m+Medelevator.RU
← Поиск публикаций
Analytica chimica acta · 2025

A microneedle sensor for in-vivo sodium ion detection in plants.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Fan Cheng-Xiao, Wang Zhuo, Wang Zhi-Hao, Wang Ao-Wen, Wang Zhong-Yi, Huang Lan

Аннотация

This study introduces a novel microneedle-type potentiometric sensor designed for the in-vivo detection of sodium ions (Na+) in plant tissues. The development of this sensor is crucial for advancing our understanding of plant responses to salinity stress. The microneedle sensor employs a highly selective Na+ ion carrier and integrates a solid-contact layer made of poly(3,4-ethylenedioxythiophene)-poly (sodium 4-styrenesulfonate) (PEDOT: PSS) prepared by electropolymerization. Due to its excellent conductivity and high chemical stability, PEDOT:PSS significantly reduces the surface impedance of the electrode, enhances charge transfer efficiency, and thereby improves the sensor's response sensitivity and stability. The sensor achieves a linear detection range of 1 × 10-2 to 1 × 10-5 M, with a slope of 56.55 ± 0.25 mV/decade and a detection limit of 1.94 × 10-6 M. The fabrication process was optimized by refining the membrane formulation, ensuring precise control over membrane thickness, and determining the optimal conditioning time, all essential for large-scale production and agricultural applications. In addition, we evaluated the sensor's ability to detect Na+ concentration changes in both artificial culture media and actual plant tissue samples. The sensor's performance was assessed through its capability to monitor Na+ concentration changes in both artificial culture media and real plant tissue samples, with results benchmarked against the standard method (ICP-OES), confirming its accuracy and reliability. Moreover, application trials involving rice seedlings validated the microneedle sensor's efficacy for in vivo detection of Na+, providing a robust tool for understanding plant physiological responses to salt stress. These findings not only offer new insights into plant adaptation mechanisms but also establish a practical platform for selecting salt-tolerant cultivars and enabling rapid salt-level assessment in agricultural practices.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты