Electrospray Generated from the Tip-Sealed Fine Glass Capillary Inserted with an Acupuncture Needle Electrode.

Usmanov Dilshadbek T, Ninomiya Satoshi, Hiraoka Kenzo, Wada Hiroshi, Nakano Hiroshi, Matsumura Masaya, Sanada-Morimura Sachiyo, Nonami Hiroshi

СтатьяПеревод в очереди

Аннотация

In electrospray, excess charges are supplied to a sample solution by the occurrence of electrochemical reactions. Recently, different versions of electrospray, e.g., dielectric barrier electrospray ionization, inductive desorption electrospray ionization, and electrostatic-ionization driven by dielectric polarization, have been reported in which the sample solution was not in direct contact with the metal electrode but separated by dielectric materials. The objective of the current work is to elucidate the mechanism of dielectric barrier electrospray. A sealed borosilicate glass capillary inserted with a fine acupuncture needle was used as a probe. A sample solution (~ 400 nL) was captured on the glass capillary tip and a positive high voltage (HV) pulse (+ 4.5 kV) was applied to the internal metal electrode. Mass spectra were measured as a function of the HV pulse width from μs to 10 s. Ions started to be detected with the pulse width of ~ 5 ms. The ion intensities increased slowly with time and reached a plateau in a few seconds. The charge distribution of cytochrome c [M + nH]n+ shifted to higher n values from a few ms to seconds. In addition to cone-jet mode normal electrospray that lasted until all the liquid sample was depleted from the glass tip, the polarization-induced electrospray ionization was observed at the early stage of the HV application. Graphical Abstract ᅟ.

Для цитирования: Usmanov Dilshadbek T, Ninomiya Satoshi, Hiraoka Kenzo, Wada Hiroshi, Nakano Hiroshi, Matsumura Masaya, Sanada-Morimura Sachiyo, Nonami Hiroshi. Electrospray Generated from the Tip-Sealed Fine Glass Capillary Inserted with an Acupuncture Needle Electrode.. Journal of the American Society for Mass Spectrometry. 2018. DOI: 10.1007/s13361-018-2062-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.