MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/acupmed-2017-011484

Медицинская библиотека · Acupuncture in medicine : journal of the British Medical Acupuncture Society · 2018

Systematic review of acupuncture placebo devices with a focus on the credibility of blinding of healthy participants and/or acupuncturists.

Zhang George Shengxi, Zhang Claire Shuiqing, Tan Hsiewe Ying, Wang Yanyi, DaCosta Cliff, Zhang Anthony Lin, Xue Charlie Changli, Xie Yi Min

СтатьяСистематический обзорПеревод в очереди

Аннотация

BACKGROUND

An ideal placebo design in clinical research should resemble the intervention under investigation to facilitate blinding, yet remain clinically inert. With regard to physical interventions such as acupuncture, a true placebo device has not been developed and validated. Since 1998, researchers have designed several placebo acupuncture devices (PADs). The three most widely used PADs are the Streitberger, the Park and the Takakura device.

AIM: This review focuses on evaluating studies of these devices, in the context of credibility of blinding (COB), assessment of penetrating pain or sensation, and de qi sensation.

METHODS

Electronic database searches were conducted in four English and two Chinese databases from their inception until November 2016. All studies included in the review were conducted on healthy participants and compared verum manual acupuncture with any of the aforementioned PADs with respect to one or more of the above three outcomes related to blinding effect.

RESULTS

The synthesised analyses of the 15 included studies showed that the Streitberger and Park placebo devices may not blind participants successfully when tested at a sensitive acupuncture point (LI4). In terms of penetrating sensation, there were significant differences between these two placebo devices and verum acupuncture when applied at this point. The Takakura device was the only PAD that had the potential to blind the acupuncturist. However, the blinding analyses of all outcome measures were inconsistent.

CONCLUSION

Overall, there were insufficient data to confirm the blinding effects of these skin-contact PADs as each device was associated with limitations that warrant further design improvements.

Для цитирования: Zhang George Shengxi, Zhang Claire Shuiqing, Tan Hsiewe Ying, Wang Yanyi, DaCosta Cliff, Zhang Anthony Lin, Xue Charlie Changli, Xie Yi Min. Systematic review of acupuncture placebo devices with a focus on the credibility of blinding of healthy participants and/or acupuncturists.. Acupuncture in medicine : journal of the British Medical Acupuncture Society. 2018. DOI: 10.1136/acupmed-2017-011484.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.