MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3415/vcot-16-03-0041

Медицинская библиотека · Veterinary and comparative orthopaedics and traumatology : V.C.O.T · 2016

Comparison of two ultrasound-guided injection techniques targeting the sacroiliac joint region in equine cadavers.

Stack John David, Bergamino Chiara, Sanders Ruth, Fogarty Ursula, Puggioni Antonella, Kearney Clodagh, David Florent

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

OBJECTIVES

To compare the accuracy and distribution of injectate for cranial (CR) and caudomedial (CM) ultrasound-guided injections of equine sacroiliac joints.

METHODS

Both sacroiliac joints from 10 lumbosacropelvic specimens were injected using cranial parasagittal (CR; curved 18 gauge, 25 cm spinal needles) and caudomedial (CM; straight 18 gauge, 15 cm spinal needles) ultrasound-guided approaches. Injectate consisted of 4 ml iodinated contrast and 2 ml methylene blue. Computed tomographical (CT) scans were performed before and after injections. Time for needle guidance and repositioning attempts were recorded. The CT sequences were analysed for accuracy and distribution of contrast.

RESULTS

Intra-articular contrast was detected in sacroiliac joints following 15/40 injections. The CR and CM approaches deposited injectate ≤2 cm from sacroiliac joint margins following 17/20 and 20/20 injections, respectively. Median distance of closest contrast to the sacroiliac joint was 0.4 cm (interquartile range [IQR]: 1.5 cm) for CR approaches and 0.6 cm (IQR: 0.95 cm) for CM approaches. Cranial injections resulted in injectate contacting lumbosacral intertransverse joints 15/20 times. Caudomedial injections were perivascular 16/20 times.

LIMITATIONS: Safety and efficacy could not be established.

CLINICAL RELEVANCE: Cranial and CM ultrasound-guided injections targeting sacroiliac joints were very accurate for periarticular injection, but accuracy was poor for intra-articular injection. Injectate was frequently found in contact with interosseous sacroiliac ligaments, as well as neurovascular and synovial structures in close vicinity of sacroiliac joints.

Для цитирования: Stack John David, Bergamino Chiara, Sanders Ruth, Fogarty Ursula, Puggioni Antonella, Kearney Clodagh, David Florent. Comparison of two ultrasound-guided injection techniques targeting the sacroiliac joint region in equine cadavers.. Veterinary and comparative orthopaedics and traumatology : V.C.O.T. 2016. DOI: 10.3415/vcot-16-03-0041.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.