MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/aas.12664

Медицинская библиотека · Acta anaesthesiologica Scandinavica · 2015

Risk evaluation for needle-nerve contact related to electrical nerve stimulation in a porcine model.

Vassiliou T, Müller H-H, Limberg S, De Andres J, Steinfeldt T, Wiesmann T

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

For performing peripheral nerve blocks, the risk for needle-nerve contact (NNC) as an adverse event for low and high current thresholds has not yet been clearly defined when nerve stimulator guided techniques were applied. This experimental study aimed to investigate the risk of NNCs when applying stimulation currents between 0.1 and 2 mA (in increments of 0.1 mA).

METHODS

Brachial plexus nerves were exposed surgically in five anesthetized pigs. An insulated needle connected to a nerve stimulator was placed at 10 mm distance to the targeted nerves. Current intensity was adjusted according to randomization (0.1-2.0 mA, increments of 0.1 mA). The needle tip was advanced toward the nerve until a motor response was elicited. The frequencies of NNCs for each of the adjusted current intensities were noted. Risks of NNCs were calculated according to the analysis of 95% confidence intervals (95% CI).

RESULTS

We executed 2000 needle placements with stimulation currents ranging from 0.1 to 2.0 mA. The risks for NNC at low current intensities were 0.85 (95% CI, 0.77-0.91) for 0.3 mA and 0.5 (95% CI, 0.4-0.6) for 0.5 mA, respectively. For high current intensities, risks of 0.13 (95% CI, 0.07-0.21) for 0.9 mA and 0.01 (95% CI, 0-0.05) for 1.1 mA were calculated.

CONCLUSIONS

In this experimental animal study, a relevant reduction in the risk of NNCs could be observed when high current intensities (0.9-1.1 mA) were applied compared to low current intensities (0.3-0.5 mA).

Для цитирования: Vassiliou T, Müller H-H, Limberg S, De Andres J, Steinfeldt T, Wiesmann T. Risk evaluation for needle-nerve contact related to electrical nerve stimulation in a porcine model.. Acta anaesthesiologica Scandinavica. 2015. DOI: 10.1111/aas.12664.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.