MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/jth.12012

Медицинская библиотека · Journal of thrombosis and haemostasis : JTH · 2012

Preanalytic variables of thrombin generation: towards a standard procedure and validation of the method.

Loeffen R, Kleinegris M-C F, Loubele S T B G, Pluijmen P H M, Fens D, van Oerle R, ten Cate H, Spronk H M H

СтатьяПоддержка исследования: вне правительства СШАВалидационное исследованиеПеревод в очереди

Аннотация

BACKGROUND

Thrombin generation assays are sensitive methods for assessment of the overall clotting potential of plasma, but, despite their common use in thrombosis research, standardization of preanalytic conditions is lacking. In order to set up a standardized protocol, we analyzed different preanalytic variables and validated the calibrated automated thrombogram method.

METHODS AND

RESULTS

Thrombin generation was assessed with 0, 1 and 5 pm tissue factor (TF). Variations in thrombin generation were mostly attributable to the type of collection tube, mainly because of variations in contact activation. The collection tube also determined the influence of other preanalytic variables on thrombin generation, e.g. the need for a discard tube, the storage of whole blood, and the centrifugation method. Regarding the collection system, blood drawn through intravenous catheters or butterfly needles showed significantly more hemolysis than blood obtained with venipuncture using conventional needles. The results showed that a discard tube is still needed for thrombin generation measurements. After blood collection, whole blood is best centrifuged immediately, to prevent activation or degradation of coagulation proteins, and a second centrifugation step at 10,000 × g is recommended. After thawing, plasma is best analyzed immediately, as storage resulted in thrombin generation results outside the 10% range of the reference sample. On the basis of these results, we set up an in-house standardized protocol, which was used for validation, resulting in coefficients of variations of < 15% for all derived parameters with both the 1 and 5 pm TF triggers.

CONCLUSION

Thrombin generation was greatly influenced by preanalytic conditions, demonstrating the need for an international standardized protocol.

Для цитирования: Loeffen R, Kleinegris M-C F, Loubele S T B G, Pluijmen P H M, Fens D, van Oerle R, ten Cate H, Spronk H M H. Preanalytic variables of thrombin generation: towards a standard procedure and validation of the method.. Journal of thrombosis and haemostasis : JTH. 2012. DOI: 10.1111/jth.12012.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.