MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1540-8167.2010.01900.x

Медицинская библиотека · Journal of cardiovascular electrophysiology · 2010

Evaluation of noncontact mapping by comparison with simultaneous multisite contact recordings in acute ischemic ventricular fibrillation.

Ganesan Anand N, Wu Gary, Liou Kevin, Pouliopoulos Jim, Barry Michael A, Thomas Stuart P

Сравнительное исследованиеСтатьяВалидационное исследованиеПеревод в очереди

Аннотация

AIM: The study aim was to determine the utility of noncontact mapping in acute ischemic ventricular fibrillation, by direct comparison with simultaneously acquired multisite contact needle recordings.

MATERIALS AND

METHODS

Noncontact mapping has emerged as a promising tool to make percutaneous high-density intracardiac electrical recordings in clinical and research settings. Previous large-animal mapping studies of ischemic VF have used electrodes in contact with the fibrillating myocardium. A previous report of noncontact mapping in VF used a single intracardiac catheter to validate noncontact recordings.

RESULTS

We studied the spontaneous onset of VF in 8 sheep, after acute occlusion of the left anterior descending coronary artery. Simultaneous unipolar recordings of endocardial electrical activation were made with the most endocardial electrode of 32 transmural plunge needles (contact electrograms; CE), and an Ensite noncontact catheter in the left ventricle (noncontact virtual electrograms; NCVE). The lag-shifted morphology cross-correlation between individual NCVE and CE pairs during VF was calculated.

DISCUSSION: The mean lag-shifted cross-correlation coefficient during manually selected sinus rhythm beats was 0.89 ± 0.006, and 0.80 ± 0.009 in VF (P < 0.05). The mean absolute time shift was 7.3 ± 0.5 ms in sinus rhythm, and 23.8 ± 0.9 ms in VF (P < 0.001). Fast Fourier transform demonstrated well-correlated dominant frequencies between CE and NCVE. VF myocardial activation maps of NCVE showed organized wavefronts, but dyssynchronous activation in CE.

CONCLUSION

These data demonstrate errors in activation timing and sequence with noncontact mapping more prominent during VF than sinus rhythm.

Для цитирования: Ganesan Anand N, Wu Gary, Liou Kevin, Pouliopoulos Jim, Barry Michael A, Thomas Stuart P. Evaluation of noncontact mapping by comparison with simultaneous multisite contact recordings in acute ischemic ventricular fibrillation.. Journal of cardiovascular electrophysiology. 2010. DOI: 10.1111/j.1540-8167.2010.01900.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.