DOI 10.1016/s1098-7339(98)90054-2

Медицинская библиотека · Regional anesthesia and pain medicine · 1998

Comparison of double-hole and single-hole pencil-point needles for spinal anesthesia with hyperbaric bupivacaine.

Puolakka R, Haasio J, Rosenberg P H, Tuominen M

Клиническое исследованиеСравнительное исследованиеКонтролируемое клиническое исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND AND

OBJECTIVES

The use of thin single-hole pencil-point (SHPP) spinal needles may be a reason for subarachnoid maldistribution of local anesthetic. A new double-hole pencil-point (DHPP) needle may be preferable because of a theoretic more uniform initial distribution of local anesthetic.

METHODS

This was a prospective, double-blinded study of 50 patients randomly selected to have spinal anesthesia using either single-hole 27-gauge (B. Braun, Melsungen, Germany) or double-hole 26-gauge (A.L.B. Medical Inc., U.S.A.) pencil-point needles. The former were inserted with the side port directed caudally and the latter with openings in both caudal and cranial direction. Two milliliters of hyperbaric 0.5% bupivacaine were injected in 1 minute, and sensory and motor block were studied at regular intervals during spinal anesthesia. All patients were interviewed on the first (personal) and the seventh (mailed questionnaire) postoperative day. Furthermore, microscopic inspection of the spinal needles was performed.

RESULTS

There were no statistically significant differences in sensory or motor block levels between the two needle types at any time during spinal anesthesia. Likewise, there was no difference in the duration of spinal block. The postanesthetic side effects (headache, backache, pricking, numbness, weakness) were similar in both groups. Light and electron microscopic examination showed resistance of the SHPP needles to tip damage. On the other hand, the DHPP needle tips seemed to be distorted quite frequently, and, even in unused needles, the tip was blunt and asymmetric.

CONCLUSION

There was no difference between the spread of analgesia using either SHPP or DHPP spinal needles. The DHPP needles appear to be vulnerable to tip damage from mechanical contact.

Для цитирования: Puolakka R, Haasio J, Rosenberg P H, Tuominen M. Comparison of double-hole and single-hole pencil-point needles for spinal anesthesia with hyperbaric bupivacaine.. Regional anesthesia and pain medicine. 1998. DOI: 10.1016/s1098-7339(98)90054-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.