DOI 10.1016/j.phro.2024.100640

Медицинская библиотека · Physics and imaging in radiation oncology · 2024

Artificial intelligence-generated targets and inter-observer variation in online adaptive radiotherapy of bladder cancer.

Åström Lina M, Sibolt Patrik, Chamberlin Hannah, Serup-Hansen Eva, Andersen Claus E, van Herk Marcel, Mouritsen Lene S, Aznar Marianne C, Behrens Claus P

СтатьяПеревод в очереди

Аннотация

BACKGROUND AND PURPOSE: Daily target re-delineation in online adaptive radiotherapy (oART) introduces uncertainty. The aim of this study was to evaluate artificial intelligence (AI) generated contours and inter-observer target variation among radiotherapy technicians in cone-beam CT (CBCT) guided oART of bladder cancer.

MATERIALS AND

METHODS

For each of 10 consecutive patients treated with oART for bladder cancer, one CBCT was randomly selected and retrospectively included. The bladder (CTV-T) was AI-segmented (CTV-TAI). Seven radiotherapy technicians independently reviewed and edited CTV-TAI, generating CTV-TADP. Contours were benchmarked against a ground truth contour (CTV-TGT) delineated blindly from scratch. CTV-TADP and CTV-TAI were compared to CTV-TGT using volume, dice similarity coefficient, and bidirectional local distance. Dose coverage (D99%>95 %) of CTV-TGT was evaluated for treatment plans optimized for CTV-TAI and CTV-TADP with clinical margins. Inter-observer variation among CTV-TADP was assessed using coefficient of variation and generalized conformity index.

RESULTS

CTV-TGT ranged from 48.7 cm3 to 211.6 cm3. The median [range] volume difference was 4.5 [-17.8, 42.4] cm3 for CTV-TADP and -15.5 [-54.2, 4.3] cm3 for CTV-TAI, compared to CTV-TGT. Corresponding dice similarity coefficients were 0.87 [0.71, 0.95] and 0.84 [0.64, 0.95]. CTV-TGT was adequately covered in 68/70 plans optimized on CTV-TADP and in 6/10 plans optimized on CTV-TAI with clinical margins. The median [range] coefficient of variation was 0.08 [0.05, 0.11] and generalized conformity index was 0.78 [0.71, 0.88] among CTV-TADP.

CONCLUSIONS

Target re-delineation in CBCT-guided oART of bladder cancer demonstrated non-isotropic inter-observer variation. Manual adjustment of AI-generated contours was necessary to cover ground truth targets.

Для цитирования: Åström Lina M, Sibolt Patrik, Chamberlin Hannah, Serup-Hansen Eva, Andersen Claus E, van Herk Marcel, Mouritsen Lene S, Aznar Marianne C, Behrens Claus P. Artificial intelligence-generated targets and inter-observer variation in online adaptive radiotherapy of bladder cancer.. Physics and imaging in radiation oncology. 2024. DOI: 10.1016/j.phro.2024.100640.