The development and validation of a questionnaire for use in the clinical setting to aid the assessment of quality of life in people with multiple myeloma

Osborne TR

Перевод в очереди

Аннотация

Background

Multiple myeloma is the second most common haematological cancer. It affects quality of life (QOL) due to physical symptoms and psychosocial impairments. Routine assessment of QOL is recommended in the clinical care of myeloma patients, yet no suitable tool exists for this purpose. Aim: To develop and validate an instrument to assess the QOL of people with multiple myeloma that is suitable for use in the clinical setting.

Methods

The Myeloma Patient Outcome Scale (MyPOS) was developed in a multi-phased study including qualitative interviews, cognitive interviews, and a cross sectional survey. Phase 1: Semi-structured qualitative interviews explored the meaning of QOL and views on existing QOL questionnaires from the patients’ perspective. Focus groups of patients and healthcare professionals further explored the meaning of QOL and desired utility of QOL questionnaires in clinical practice. Purposive sampling used throughout except patient focus groups due to feasibility. Thematic analysis identified emergent themes and used to develop a theoretical model of QOL in myeloma. Phase 2: Above findings used to develop a prototype MyPOS. Cognitive interviews used to evaluate and refine the MyPOS in ... (continues)

Для цитирования: Osborne TR. The development and validation of a questionnaire for use in the clinical setting to aid the assessment of quality of life in people with multiple myeloma. 2016.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.