MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2215/cjn.16481221

Медицинская библиотека · Clinical journal of the American Society of Nephrology : CJASN · 2022

Automated Determination of Left Ventricular Function Using Electrocardiogram Data in Patients on Maintenance Hemodialysis.

Vaid Akhil, Jiang Joy J, Sawant Ashwin, Singh Karandeep, Kovatch Patricia, Charney Alexander W, Charytan David M, Divers Jasmin, Glicksberg Benjamin S, Chan Lili, Nadkarni Girish N

СтатьяПоддержка NIH: внешняя программаПеревод в очереди

Аннотация

BACKGROUND AND

OBJECTIVES

Left ventricular ejection fraction is disrupted in patients on maintenance hemodialysis and can be estimated using deep learning models on electrocardiograms. Smaller sample sizes within this population may be mitigated using transfer learning.

DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS: We identified patients on hemodialysis with transthoracic echocardiograms within 7 days of electrocardiogram using diagnostic/procedure codes. We developed four models: (1) trained from scratch in patients on hemodialysis, (2) pretrained on a publicly available set of natural images (ImageNet), (3) pretrained on all patients not on hemodialysis, and (4) pretrained on patients not on hemodialysis and fine-tuned on patients on hemodialysis. We assessed the ability of the models to classify left ventricular ejection fraction into clinically relevant categories of ≤40%, 41% to ≤50%, and >50%. We compared performance by area under the receiver operating characteristic curve.

RESULTS

We extracted 705,075 electrocardiogram:echocardiogram pairs for 158,840 patients not on hemodialysis used for development of models 3 and 4 and n=18,626 electrocardiogram:echocardiogram pairs for 2168 patients on hemodialysis for models 1, 2, and 4. The transfer learning model achieved area under the receiver operating characteristic curves of 0.86, 0.63, and 0.83 in predicting left ventricular ejection fraction categories of ≤40% (n=461), 41%-50% (n=398), and >50% (n=1309), respectively. For the same tasks, model 1 achieved area under the receiver operating characteristic curves of 0.74, 0.55, and 0.71, respectively; model 2 achieved area under the receiver operating characteristic curves of 0.71, 0.55, and 0.69, respectively, and model 3 achieved area under the receiver operating characteristic curves of 0.80, 0.51, and 0.77, respectively. We found that predictions of left ventricular ejection fraction by the transfer learning model were associated with mortality in a Cox regression with an adjusted hazard ratio of 1.29 (95% confidence interval, 1.04 to 1.59).

CONCLUSION

A deep learning model can determine left ventricular ejection fraction for patients on hemodialysis following pretraining on electrocardiograms of patients not on hemodialysis. Predictions of low ejection fraction from this model were associated with mortality over a 5-year follow-up period.

PODCAST: This article contains a podcast at https://www.asn-online.org/media/podcast/CJASN/2022_06_06_CJN16481221.mp3.

Для цитирования: Vaid Akhil, Jiang Joy J, Sawant Ashwin, Singh Karandeep, Kovatch Patricia, Charney Alexander W, Charytan David M, Divers Jasmin, Glicksberg Benjamin S, Chan Lili, Nadkarni Girish N. Automated Determination of Left Ventricular Function Using Electrocardiogram Data in Patients on Maintenance Hemodialysis.. Clinical journal of the American Society of Nephrology : CJASN. 2022. DOI: 10.2215/cjn.16481221.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.