BACKGROUND

Surgical intervention for spontaneous pneumothorax typically includes mechanical pleurodesis that frequently utilizes a Bovie scratch pad given its universal presence, low cost and ease of use. The pad is folded on itself after dividing it in half, allowing easier passage through the smaller incisions. However, unintentional foreign body retention may occur during the course of an operation leading to reoperations or even worse complications. This case is reported to raise awareness that dividing the scratch pad may allow the embedded radio-opaque marker to fall out and become retained as a foreign body.

CASE PRESENTATION: The patient is a 41 year-old female who presented with shortness of breath secondary to spontaneous pneumothorax. Chest CT scan showed apical blebs. The patient underwent video assisted thorascopic surgery (VATS) with bleb resection and mechanical pleurodesis using a divided and folded bovie scratch pad. Postoperative chest x-ray showed a retained foreign body. Reoperation confirmed this to be the radio-opaque marker of the scratch pad and was removed. The patient did well and was discharged the following day.

CONCLUSION

Dividing the bovie scratch pad may damage and "weaken" the product allowing the radio- opaque marker to fall out during its use for pleurodesis and should be discouraged. Recommendation is made of using the scratch pad as a whole and not dividing it. Retained radio-opaque marker of bovie scratch pad during VATS mechanical pleurodesis.

Для цитирования: Akras Deena, Raymond Daniel, Akhrass Rami, Murthy Sudish. Retention of Bovie scratch pad radio-opaque marker during VATS Pleurodesis: case report.. Journal of cardiothoracic surgery. 2021. DOI: 10.1186/s13019-021-01497-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.