MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/pd.6078

Медицинская библиотека · Prenatal diagnosis · 2021

Pregnancy outcomes of fetuses with congenital heart disease after a prenatal diagnosis with chromosome microarray.

Zhang Zhu, Hu Ting, Wang Jiamin, Hu Rui, Li Qinqin, Xiao Like, Liao Na, Liu Zhushu, Wang He, Liu Shanling

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To evaluate the pregnancy outcomes of fetuses with congenital heart disease (CHD) after chromosome microarray (CMA)-based prenatal diagnosis.

METHOD: Amniocentesis was performed in 1035 pregnant women carrying fetuses with CHD between September 2014 and December 2019. Chromosomal aberrations in fetuses with CHD were evaluated using CMA. The pregnancy outcomes were followed up from 6 months to 5 years.

RESULTS

The overall CHD detection rate by CMA was 10.1% (105/1035; 50 fetuses: aneuploidy, 55 fetuses: pathogenic or likely pathogenic copy number variations). Among 1003 fetuses who were followed up, 4, 236, 763, and 18 cases were of miscarriages, pregnancy termination, live births, and postnatal deaths, respectively. Self-healed CHD was observed in 401 (52.6%) fetuses. The pregnancy termination rate of fetuses with chromosomal anomalies was significantly higher than that of fetuses without chromosomal anomalies (93.1% vs. 15.5%, p < 0.001). However, other pregnancy outcomes, including mortality, preterm labor, and low-weight birth rate, were similar between the two groups.

CONCLUSION

The outcome of CMA is an important factor influencing parents' choice of whether to continue the pregnancy. Self-healing rate of prenatal diagnosed CHD is high. The mortality and morbidity of fetuses with CHD following prenatal CMA testing are relatively low.

Для цитирования: Zhang Zhu, Hu Ting, Wang Jiamin, Hu Rui, Li Qinqin, Xiao Like, Liao Na, Liu Zhushu, Wang He, Liu Shanling. Pregnancy outcomes of fetuses with congenital heart disease after a prenatal diagnosis with chromosome microarray.. Prenatal diagnosis. 2021. DOI: 10.1002/pd.6078.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.