MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1590/s0100-72032008000700004

Медицинская библиотека · Revista brasileira de ginecologia e obstetricia : revista da Federacao Brasileira das Sociedades de Ginecologia e Obstetricia · 2008

[Correlation between echographic cardiac measurements and hemoglobin deficit in fetus of red cell alloimmunized pregnancies].

Hanan Marília Zicker, Cabral Antônio Carlos Vieira, Pereira Alamanda Kfoury, Leite Henrique Vitor, Reis Zilma Nogueira

СтатьяПеревод в очереди

Аннотация

PURPOSE: to verify the correlation between ultrasonography heart measures and hemoglobin deficit in fetuses of alloimmunized pregnant women.

METHODS

a transversal study, including 60 fetuses, with 21 to 35 weeks of gestational age, from 56 isoimmunized pregnant women. A number of 139 procedures were performed. Before cordocentesis for the collection of fetal blood, cardiac measures and femur length (FL) were assessed by ultrasonography. The external biventricular diameter (EBVD) was obtained by measuring the distance between the epicardic external parts at the end of the diastole, with the M-mode cursor perpendicular to the interventricular septum, in the atrioventricular valves. The measure of the atrioventricular diameter (AVD) was obtained by positioning the same cursor along the interventricular septum, evaluating the distance between the heart basis and apex. The FL was determined from the trochanter major to the distal metaphysis. The cardiac circumference (CC) was also calculated. To adjust the cardiac measure to the gestational age, each of these measures were divided by the FL measure. Hemoglobin concentration has been determined by spectrophotometry with the Hemocue system. Hemoglobin deficit calculation was based in the Nicolaides's normality curve.

RESULTS

direct and significant correlations were observed between the cardiac measures evaluated and the hemoglobin deficit. To predict moderate and severe anemia, the sensitivity and specificity found were 71.7 and 66.3% for EBVD and FL, 65.8 and 62.4% for AVD and FL, and 73.7 and 60.4% for CC and FL, respectively.

CONCLUSIONS

ultrasonography cardiac measures assessed from fetuses of isoimmunized pregnant women correlate directly with hemoglobin deficit.

Для цитирования: Hanan Marília Zicker, Cabral Antônio Carlos Vieira, Pereira Alamanda Kfoury, Leite Henrique Vitor, Reis Zilma Nogueira. [Correlation between echographic cardiac measurements and hemoglobin deficit in fetus of red cell alloimmunized pregnancies].. Revista brasileira de ginecologia e obstetricia : revista da Federacao Brasileira das Sociedades de Ginecologia e Obstetricia. 2008. DOI: 10.1590/s0100-72032008000700004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.