MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s11517-012-0972-y

Медицинская библиотека · Medical & biological engineering & computing · 2012

Using three-dimensional multigrid-based snake and multiresolution image registration for reconstruction of cranial defect.

Liao Yuan-Lin, Lu Chia-Feng, Wu Chieh-Tsai, Lee Jiann-Der, Lee Shih-Tseng, Sun Yung-Nien, Wu Yu-Te

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

In cranioplasty, neurosurgeons use bone grafts to repair skull defects. To ensure the protection of intracranial tissues and recover the original head shape for aesthetic purposes, a custom-made pre-fabricated prosthesis must match the cranial incision as closely as possible. In our previous study (Liao et al. in Med Biol Eng Comput 49:203-211, 2011), we proposed an algorithm consisting of the 2D snake and image registration using the patient's own diagnostic low-resolution and defective high-resolution computed tomography (CT) images to repair the impaired skull. In this study, we developed a 3D multigrid snake and employed multiresolution image registration to improve the computational efficiency. After extracting the defect portion images, we designed an image-trimming process to remove the bumped inner margin that can facilitate the placement of skull implants without manual trimming during surgery. To evaluate the performance of the proposed algorithm, a set of skull phantoms were manufactured to simulate six different conditions of cranial defects, namely, unilateral, bilateral, and cross-midline defects with 20 or 40% skull defects. The overall image processing time in reconstructing the defect portion images can be reduced from 3 h to 20 min, as compared with our previous method. Furthermore, the reconstruction accuracies using the 3D multigrid snake were superior to those using the 2D snake.

Для цитирования: Liao Yuan-Lin, Lu Chia-Feng, Wu Chieh-Tsai, Lee Jiann-Der, Lee Shih-Tseng, Sun Yung-Nien, Wu Yu-Te. Using three-dimensional multigrid-based snake and multiresolution image registration for reconstruction of cranial defect.. Medical & biological engineering & computing. 2012. DOI: 10.1007/s11517-012-0972-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.