m+Medelevator.RU
← Поиск публикаций
Journal of pain research · 2018

An innovative technique for osteoporotic vertebral compression fractures - vertebral osteotome with side-opening cannula.

Название и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

He X, Liu Y, Zhang J, Jia S, Meng Y, Huang Y, Wu Q, Hao D

Аннотация

ObjectiveThis study is to assess an innovative technique - a vertebral osteotome (VO) combined with side-opening injection cannula for percutaneous vertebroplasty (PVP).MethodsA retrospective study by propensity score matching. From January 2016 to April 2016, 63 patients who were diagnosed with monosegmental osteoporotic vertebral compression fracture received the innovative technique. The epidemiologic data, surgical indexes, and recovery outcomes were collected in the follow-up period. Propensity score matching identified 63 pairs form historical controls by traditional unilateral PVP approach in 2015 using six independent variables: age, sex, preoperative visual analog score (VAS), Oswestry Disability Index (ODI), body mass index, and bone mineral density.ResultsThe surgical duration and cement distribution were longer and larger in patients by VO method. Besides, postoperative VAS and ODI in the VO group were lower than those in the control group. However, there were no differences in radiation exposure times, improvement of Cobb angle, cement leakage, or adjacent vertebral fracture between two groups. Cement volume in the VO group was less than that in the control group.ConclusionThis new innovative technique makes PVP safe and effective. Although it lasts longer, the restoration rate of vertebral height and cement distribution can be improved, which contributes to a better pain relief.

Перевод полного текста: Перевод в очереди

Читать найденный полный текст

https://creativecommons.org/licenses/by-nc/3.0/ The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License ( http://creativecommons.org/licenses/by-nc/3.0/ ). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed.

Introduction

Osteoporotic vertebral compression fracture (OVCF) was a menace to the elderly generation, which caused diminished quality of life due to pain and deformity. 1 More than 25% of women aged 50 years and older will have one or more vertebral compression fractures by 2025. 2 Percutaneous vertebroplasty (PVP) was a minimally invasive surgical procedure for the management of OVCF. 3 It also provided rapid pain relief and stabilization of the fractured vertebral bodies. 4 PVP was necessary after the failure of 2–3 weeks of conservative treatment including pain medication and physiotherapy, which had gained popularity as a new treatment of OVCF. 5

PVP was one of the optimal treatments for OVCF, but the matter of surgical approach selection remained controversial. Traditional bilateral PVP was shown to be safe and effective for OVCF. 6 , 7 Nevertheless, it showed increased surgery time and injected cement volume, and the risk of bone cement leakage was twice that of the unilateral approach. 8 The unilateral PVP would be an attractive alternative to the traditional bilateral PVP owing to theoretical speed, safety, and lower X-ray irradiation. 9 Meanwhile, asymmetric distribution of bone cement leading to spinal instability in the vertebral body by using unilateral technique had been reported in a research. 10 For achieving the advantages of both unilateral and bilateral approach, we developed an innovative technique proceeding PVP and compared it with a traditional method.

Methods

Patients

Between January 2016 and April 2016, patients who were diagnosed as monosegmental OVCF were recruited in our study. The inclusion criteria were as follows: 1) tenderness or percussion pain at fractured vertebral body surface in the recent 1 year; 2) vertebrae fracture without any pressure in spinal canal or nerve lesion by X-rays; 3) osteoporosis (diagnosed by bone mineral density [BMD], calculated as T value ≤−2.5); 4) intact vertebral posterior wall; 5) new fractures without any other fractures in vertebrae.

The excluding criteria were as follows: 1) patients lost to follow-up; 2) a patient history of previous PVP or percutaneous kyphoplasty; 3) clinical or imaging evidence of metastatic bone tumor or multiple myeloma; 4) complications in endocrine system (such as diabetes, thyroid dysfunction, and so on).

Each patient took physical examinations and spinal radiographs on the day before surgery and 3 months after surgery. The study protocol was approved by the ethics committee of Hong Hui Hospital, Xi’an Jiaotong University, and informed consent was obtained from all patients.

We confirmed that all methods were carried out in accordance with relevant guidelines and regulations of our licensing committee. We confirmed that all experimental protocols were approved by licensing committee of Xi’an HongHui Hospital, and all patients were informed and provided written informed consent. The informed consent for publication of identifying images has been approved by the relevant patient.

Devices composition

A series of novel devices were invented for the application of unilateral PVP in the present study. The most important part was vertebral osteotome (VO; Figure 1A ). The ending of VO could bend from 0° to 90°, which was helpful to make a curved cavity in the vertebral body. Surgeons could rotate the handle knob at the bottom of the VO to control the bending degrees. It could work better with side-opening injection cannula ( Figure 1B ). Compared to the traditional ones, there was an opening on the side of our cannula. So, the device had the ability of directional bone cement delivery. The handspike was the instrument that can go through the cannula, which could promote the movement of bone cement in the cannula. Then the bone cement could be injected into vertebral body through the side-opening injection cannula by the cement handspike ( Figure 1C ). Now the VO and its accessorial devices are commercially used in the hospital.

Surgical procedures

The surgery was performed under general anesthesia and unilateral approach. X-ray fluoroscopy was used throughout the whole procedure. A skin incision was made on the pedicle level of the fractured vertebral body. Then the needle and pin were placed via the stab incision. The pin was not removed until it reached 2–3 mm depth of posterior vertebral body wall. Next, a wire pin was fixed into the vertebral body. The needle pipe was removed and a working cannula was constructed. Subsequently, the VO was inserted through the cannula after the wire pin was withdrawn. By using its flexible end, VO could make a curved cavity in the fractured vertebral body. The resulting cavity was filled with polymethylmethacrylate (PMMA) cement, which was injected by cement handspike through the side-opening injection cannula ( Figure 2 ).

Research indexes

Research indexes included three parts: surgery outcomes, clinical assessment, and radiographic outcomes. All pre- operative and postoperative data were recorded on the day before surgery and 3 months after surgery.

Surgery outcomes: The cement volume, surgical duration, and radiation exposure times were recorded by the operators during the surgery process.

Clinical assessment: It was evaluated using the Oswestry Disability Index (ODI) and the visual analog scale. Both preoperative and postoperative ODI and visual analog score (VAS) were recorded.

Radiographic outcomes: BMD was measured by X-ray radiographic absorptiometry. The restoration rate of vertebral height was calculated as (postoperative vertebral height − preoperative vertebral height)/(predicted primary vertebral height − preoperative vertebral height)*100%. The predicted primary vertebral height was the mean height of two vertebrae adjacent to the injured vertebra. The improvement of Cobb angle was calculated as follows: (preoperative Cobb angle − postoperative Cobb angle). Cobb angle was measured from the superior endplate of vertebra one level above the fractured vertebra to the inferior endplate of the vertebral one level below the fractured vertebra on the lateral X-ray image. The cement distribution was calculated as the mean ratio of bright areas to the whole fractured vertebra area both in the anteroposterior (AP) and lateral views under X-rays during the surgery ( Figure 3 ). Cement leakage was defined as any presence of extravertebral high cement signal observed by X-ray. Adjacent vertebral fracture postoperatively was defined with any vertebral fracture next to the treated vertebral body.

Statistical analysis

Propensity Score Matching (PSM) was used in our analysis. Propensity matched pairs were identified by matching on the following six independent variables: age, sex, preoperative VAS, preoperative ODI, BMI, and BMD. Propensity matching of subjects was performed by the method of nearest distance with a 1:1 ratio ( Figure 4 ). Data were analyzed using the SAS9.1 software (SAS Institute Inc, Cary, NC, USA). Numeric variables were expressed as mean ± SD. Nominal variables were expressed as numbers (percentage). The chi- squared test was used for the univariate analyses of categorical data and the independent t -test was used for the univariate analyses of continuous data between the VO group and the control group. The statistical significance was set at P <0.05.

Results

General information

A total of 20 men and 43 women with 45 lumber vertebras and 18 thoracic vertebras underwent PVP by VO in our hospital. The mean age of patients was 59.4±10.0 years (45–86 years). BMI and BMD were 22.83±3.16 kg/m 2 and −3.6±0.7, respectively. After surgery, the VAS decreased from 7.2±1.8 to 2.9±1.5 ( t =13.855, P <0.001), which indicated an obvious pain relief. The ODI also improved from 54.3±5.1 to 12.4±1.7 ( t =60.499, P <0.001).

To compare the VO method with the traditional technique method in proceeding surgery, we identified data from records of 550 patients with OVCF who underwent PVP in 2015. Of all 550 patients, 80 patients received a bilateral surgical approach, 67 patients had multisegment OVCFs, 33 patients were lost to follow-up, 18 patients had endocrine system diseases, and six patients were diagnosed with bone tumor and multiple myeloma. There were only 346 patients left in the historical controls. After stratifying and matching, 63 patients in the VO group were paired with 63 patients in the control group. Moreover, there were no statistically significant differences in age, sex, BMI, BMD, preoperative VAS, or ODI between two groups ( Table 1 ).

Surgery outcomes comparison

The surgical duration and cement distribution in the VO group were 27.7±5.4 minutes and 0.64±0.20, respectively. They were both larger than that in the control group ( t =4.391, P <0.001; t =7.860, P <0.001). Cement volume in the VO group was less than that in the control group (3.5±0.8 vs 4.0±1.0, t =−2.890, P =0.005). However, the total time of fluoroscopic radiation exposure in the VO group was 13.4±3.7, which showed no differences with that in the control group ( Table 2 ).

Clinical assessment and radiographic outcomes comparison

VAS was decreased obviously at 3 months after surgery in each group, whereas postoperative VAS in the VO group was significantly lower than that in the control group (2.9±1.5 vs 4.2±1.5, t =−4.823, P <0.001). The postoperative ODI in the VO group was also better than that in the control group (12.4±1.7 vs 19.0±1.9, t =−20.534, P <0.001). Besides, the restoration rate of vertebral height in the VO group was higher than that in the control group (45.79±9.46 vs 30.23±16.43, t =6.513, P <0.001). The improvement of Cobb angle was 4.08±1.10° in the VO group, which showed no statistically differences with that in the control group.

A total of two patients experienced cement leakage in the follow-up period. The site of leakage was intervertebral disc, but no one had clinical manifestations. Only one patient had an adjacent vertebral fracture in L3 level. The pain disappeared after reoperation. There were no differences in complications between VO group and the control group ( Table 3 ).

Discussion

Effects of PVP in treating OVCFs have been demonstrated in many studies. 11 – 13 It brings the pain relief and normal activities to patients with OVCF. At the same time, problems such as asymmetric distribution of bone cement, refractures after operation, and vertebrae recollapse also exist in traditional PVP method 14 . The principal goal of surgery for treating OVCF is to restore the height of fractured vertebral body and to reduce its kyphosis deformity. 15 Therefore, the restoration rate of vertebral height was used as radiographic outcomes of PVP in our study. The mechanism behind the restoration of vertebral height during vertebroplasty is probably due to two factors. First, it is a well-known phenomenon in orthopedic literature to experience improvement of fracture height simply by placing the patient prone. Second, the pressure and volume of PMMA cement injected help to preserve positional changes and might restore fracture height. 16 The patients with VO had a higher restoration rate of vertebral height than that in the control group. Because the curved tip of VO could reach the inner of vertebral body, bone cement could be injected into the cracks and cavities where the VO could reach. In the traditional method, if we wanted to inject the bone cement into the inner cracks of vertebral body, the only way was improving the injection pressure, which contributed to a more consumption of cement volume, even a new crack in vertebral body or the damage to the posterior wall of the vertebral body, especially in old patients with osteoporosis. Too much cement volume will lead to too much recovery of vertebral height that may increase the tension around vertebral soft tissues and lead to improvement of stress in augmented vertebrae and their adjacent sections, and instability among vertebrae. 17 Meanwhile, anterior and posterior height losses are also important signs: this may indicate spinal canal compromise and vertebral collapse in the future. 18 To achieve the adequate balanced point of vertebral body, VO could solve this problem.

Several studies had showed that no association was found between the injected cement volume and pain relief. 19 , 20 On the contrary, it was associated with an increased risk of complications. A clinical study on the relationship between the volumetric analysis of cement in vertebroplasty with clinical outcome and complications showed that a volume larger than 11.65% led to a significantly increased incidence of leakage and adjacent fractures. 21 An in vivo study following PVP showed that for restoration of vertebral body strength and stiffness, vertebral body cement filling degrees of 16% and 30% were required, respectively. 22 Interestingly, although VO creates a cavity in the vertebral body, cement volume is less by the use of our new instrument. The only explanation is the less injection pressure used by VO. To achieve a better surgical effect, a uniform diffusion of bone cement in vertebral body is required. 23 In the traditional method, cannula is fixed in the vertebral body. Diffusion of bone cement can be controlled by the injection pressure. VO has already reduced the resistance of vertebral body to bone cement. Although, no essays have demonstrated that high injection pressure would contribute to more volume of bone cement. In our study, the volume of bone cement in the VO group was less than that in the control group. The cavity made by VO does not mean more consumption of bone cement. On the contrary, traditional method with high injection pressure makes itself a cost of bone cement. Since minimal required cement volume for both pain relief and restoration of mechanical properties is recommended. It indicates that VO is a safe device.

Except for cement volume, cement distribution is also an important indicator of operative complications and postoperative recovery. Zhang et al found that patients with bone cement distributed around both the upper and lower endplates had the lowest rate of experiencing recompression compared to other patterns of bone cement distribution. 24 Previous studies showed that a larger bone–cement interface would achieve a relatively higher vertebral strength and reduce leakage rate. 25 It was suggested that the cement should spread through the vertebral body in a controlled manner that appeared fluoroscopically as a “uniformly expanding cloud” 26 . Insufficient cement distribution in the fractured area might lead to unrelieved pain after PVP. An asymmetrical cement distribution around fractured area was more likely to induce recollapse of augmented vertebrae because they increased maximum von Mises stress in the cancellous bone and cortical bone significantly. 27 In the present study, we used the mean ratio of bright areas to the whole vertebra area both in the AP and lateral views under X-rays as the measurement of cement distribution. It showed that when the cement volume is constant, the more extensive the cement distribution is, the better the surgery outcomes are. 28 The same indexes were used in this study. The cement distribution in the VO group was larger than that in the control group. Although the relationship between the cement distribution and pain relief was not explored, the lower VAS and ODI demonstrated the better recovery by VO method.

The end of VO had the ability of creating large curvature so that it could not destroy posterior vertebral wall even with much force. To reduce the leakage during PVP, injected cement should be kept away from posterior vertebral wall. Depression of the thoracolumbar posterior vertebral wall might be informative for the estimation of cement location on C-arm images. 29 Our new device VO with side-opening cannula is operated in the unilateral approach. The cannula ensures the directional transport of bone cement and reduces its impact force to the posterior vertebral wall. There is no significant difference in cement leakage between the VO group and the traditional method group, which indicates that VO will not increase the risk of cement leakage.

Limitations

The main limitations of our study are relatively small sample size and short follow-up period. However, we performed PSM method to compensate for the size shortcoming. It is still meaningful in finding the characteristics and advantages of VO.

Conclusion

The VO device with side-opening bone filler device makes PVP safe and effective, with less cement consumption. Although it lasts longer, the restoration rate of vertebral height and cement distribution can be improved, which contributes to a better pain relief.

Ethics approval

All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional research committee and with the 1964 Declaration of Helsinki and its later amendments or comparable ethical standards.

Disclosure

The authors report no conflicts of interest in this work.

References

1 Han SL Wan SL Li QT Is vertebroplasty a risk factor for subsequent vertebral fracture, meta-analysis of published evidence? Osteoporos Int 2015 26 1 113 122 25149856 10.1007/s00198-014-2848-5

2 Savage JW Schroeder GD Anderson PA Vertebroplasty and kyphoplasty for the treatment of osteoporotic vertebral compression fractures J Am Acad Orthop Surg 2014 22 10 653 664 25281260 10.5435/JAAOS-22-10-653

3 Esses SI Mcguire R Jenkins J The treatment of symptomatic osteoporotic spinal compression fractures J Am Acad Orthop Surg 2011 19 3 176 182 21368099 10.5435/00124635-201103000-00007

4 Huang H He S Fang W Percutaneous vertebroplasty for treatment of painful osteoporotic vertebral compression fractures: a retrospective analysis of clinical efficacy Zhonghua Yi Xue Za Zhi 2014 94 27 2119 2222 25327858

5 Sebaaly A Nabhane L Issa El Khoury F Kreichati G El Rachkidi R Vertebral augmentation: state of the art Asian Spine J 2016 10 2 370 376 27114782 10.4184/asj.2016.10.2.370 PMC4843078

6 Liu J Li X Tang D Comparing pain reduction following vertebroplasty and conservative treatment for osteoporotic vertebral compression fractures: a meta-analysis of randomized controlled trials Pain Physician 2013 16 5 455 464 24077192

7 Chen C Bian J Zhang W Zhang W Zhao C Wei H Unilateral versus bilateral vertebroplasty for severe osteoporotic vertebral compression fractures J Spinal Disord Tech 2014 27 8 E301 E304 24901876 10.1097/BSD.0000000000000118

8 Guo Z Xq L The effect comparison of the percutaneous vertebroplasty for osteoporotic vertebral compression fractures via the unilateral and bilateral transpedicular approach Chin J Mod Oper Surg 2015 19 439 442

9 Zhang L Liu Z Wang J Unipedicular versus bipedicular percutaneous vertebroplasty for osteoporotic vertebral compression fractures: a prospective randomized study BMC Musculoskelet Disord 2015 16 145 26071690 10.1186/s12891-015-0590-6 PMC4465457

10 Yan L Jiang R He B Liu T Hao D A comparison between unilateral transverse process-pedicle and bilateral puncture techniques in percutaneous kyphoplasty Spine 2014 39 26 Spec No B19 B26 25504098 10.1097/BRS.0000000000000493

11 van Meirhaeghe J Bastian L Boonen S A randomized trial of balloon kyphoplasty and nonsurgical management for treating acute vertebral compression fractures: vertebral body kyphosis correction and surgical parameters Spine 2013 38 12 971 983 23446769 10.1097/BRS.0b013e31828e8e22 PMC3678891

12 Heran MK Legiehn GM Munk PL Current concepts and techniques in percutaneous vertebroplasty Orthop Clin North Am 2006 37 3 409 434 16846770 10.1016/j.ocl.2006.05.001

13 Zhang LG Gu X Zhang HL Unilateral or bilateral percutaneous vertebroplasty for acute osteoporotic vertebral fracture: a prospective study J Spinal Disord Tech 2015 28 2 E85 E88 25099973 10.1097/BSD.0000000000000147

14 Chen B Li Y Xie D Yang X Zheng Z Comparison of unipedicular and bipedicular kyphoplasty on the stiffness and biomechanical balance of compression fractured vertebrae Eur Spine J 2011 20 8 1272 1280 21384203 10.1007/s00586-011-1744-3 PMC3175856

15 Lunt M O’Neill TW Felsenberg D Characteristics of a prevalent vertebral deformity predict subsequent vertebral fracture: results from the European Prospective Osteoporosis Study (EPOS) Bone 2003 33 4 505 513 14555253 10.1016/s8756-3282(03)00248-5

16 Teng MM Wei CJ Wei LC Kyphosis correction and height restoration effects of percutaneous vertebroplasty AJNR Am J Neuroradiol 2003 24 9 1893 1900 14561624 PMC7976281

17 Kim YJ Lee JW Kim KJ Percutaneous vertebroplasty for intravertebral cleft: analysis of therapeutic effects and outcome predictors Skeletal Radiol 2010 39 8 757 766 20143063 10.1007/s00256-009-0866-8

18 Seo JY Kwon YS Kim KJ Shin JY Kim YH Ha KY Clinical importance of posterior vertebral height loss on plain radiography when conservatively treating osteoporotic vertebral fractures Injury 2017 48 7 1503 1509 28477991 10.1016/j.injury.2017.04.057

19 Jacobson RE Granville M Hatgis J Berti A Low volume vertebral augmentation with Cortoss® cement for treatment of high degree vertebral compression fractures and vertebra plana Cureus 2017 9 2 e1058 28367395 10.7759/cureus.1058 PMC5364091

20 Liebschner MA Rosenberg WS Keaveny TM Effects of bone cement volume and distribution on vertebral stiffness after vertebroplasty Spine 2001 26 14 1547 1554 11462084 10.1097/00007632-200107150-00009

21 Jin YJ Yoon SH Park KW The volumetric analysis of cement in vertebroplasty: relationship with clinical outcome and complications Spine 2011 36 12 E761 E772 21289575 10.1097/BRS.0b013e3181fc914e

22 Molloy S Mathis JM Belkoff SM The effect of vertebral body percent- age fill on mechanical behavior during percutaneous vertebroplasty Spine 2003 28 14 1549 1554 12865843

23 Dong JK Tae WK Kwan HP The proper volume and distribution of cement augmentation on percutaneous vertebroplasty J Korean Neurosurg 2010 48 125 128 10.3340/jkns.2010.48.2.125 PMC2941854 20856660

24 Zhang L Wang Q Wang L Shen J Zhang Q Sun C Bone cement distribution in the vertebral body affects chances of recompression after percutaneous vertebroplasty treatment in elderly patients with osteoporotic vertebral compression fractures Clin Interv Aging 2017 12 431 436 28260871 10.2147/CIA.S113240 PMC5327848

25 Tan QC Wu JW Peng F Augmented PMMA distribution: improvement of mechanical property and reduction of leakage rate of a fenestrated pedicle screw with diameter-tapered perforations J Neurosurg Spine 2016 24 6 971 977 26849712 10.3171/2015.10.SPINE141275

26 Baroud G Crookshank M Bohner M High-viscosity cement significantly enhances uniformity of cement filling in vertebroplasty: an experimental model and study on cement leakage Spine 2006 31 22 2562 2568 17047545 10.1097/01.brs.0000240695.58651.62

27 Liang D Ye LQ Jiang XB Biomechanical effects of cement distribution in the fractured area on osteoporotic vertebral compression fractures: a three-dimensional finite element analysis J Surg Res 2015 195 1 246 256 25634828 10.1016/j.jss.2014.12.053

28 He X Li H Meng Y Percutaneous kyphoplasty evaluated by cement volume and distribution: an analysis of clinical data Pain Physician 2016 19 7 495 506 27676666

29 Lin BJ Li CC Ma HI Cc L Hi M Intradural cement leakage after percutaneous vertebroplasty Turk Neurosurg 2015 25 6 940 942 26617146 10.5137/1019-5149.JTN.11079-14.1