MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.mimet.2011.04.020

Медицинская библиотека · Journal of microbiological methods · 2011

Dry-reagent gold nanoparticle-based lateral flow biosensor for the simultaneous detection of Vibrio cholerae serogroups O1 and O139.

Yu Choo Yee, Ang Geik Yong, Chua Ang Lim, Tan Elina Husni, Lee Su Yin, Falero-Diaz Gustavo, Otero Oscar, Rodríguez Irelio, Reyes Fátima, Acosta Armando, Sarmiento María E, Ghosh Santanu, Ramamurthy Thandavarayan, Yean Yean Chan, Lalitha Pathabhiraman, Ravichandran Manickam

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Cholera is a communicable disease caused by consumption of contaminated food and water. This potentially fatal intestinal infection is characterised by profuse secretion of rice watery stool that can rapidly lead to severe dehydration and shock, thus requiring treatment to be given immediately. Epidemic and pandemic cholera are exclusively associated with Vibrio cholerae serogroups O1 and O139. In light of the need for rapid diagnosis of cholera and to prevent spread of outbreaks, we have developed and evaluated a direct one-step lateral flow biosensor for the simultaneous detection of both V. cholerae O1 and O139 serogroups using alkaline peptone water culture. Serogroup specific monoclonal antibodies raised against lipopolysaccharides (LPS) were used to functionalize the colloidal gold nanoparticles for dual detection in the biosensor. The assay is based on immunochromatographic principle where antigen-antibody reaction would result in the accumulation of gold nanoparticles and thus, the appearance of a red line on the strip. The dry-reagent dipstick format of the biosensor ensure user-friendly application, rapid result that can be read with the naked eyes and cold-chain free storage that is well-suited to be performed at resource-limited settings.

Для цитирования: Yu Choo Yee, Ang Geik Yong, Chua Ang Lim, Tan Elina Husni, Lee Su Yin, Falero-Diaz Gustavo, Otero Oscar, Rodríguez Irelio, Reyes Fátima, Acosta Armando, Sarmiento María E, Ghosh Santanu, Ramamurthy Thandavarayan, Yean Yean Chan, Lalitha Pathabhiraman, Ravichandran Manickam. Dry-reagent gold nanoparticle-based lateral flow biosensor for the simultaneous detection of Vibrio cholerae serogroups O1 and O139.. Journal of microbiological methods. 2011. DOI: 10.1016/j.mimet.2011.04.020.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.