MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5694/mja2.51589

Медицинская библиотека · The Medical journal of Australia · 2022

D-dimer testing for early detection of venom-induced consumption coagulopathy after snakebite in Australia (ASP-29).

Isbister Geoffrey K, Noutsos Tina, Jenkins Shane, Isoardi Katherine Z, Soderstrom Jessamine, Buckley Nicholas A

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To assess the accuracy and marginal value of quantitative D-dimer testing for diagnosing venom-induced consumption coagulopathy (VICC) in people bitten by Australian snakes.

DESIGN,

SETTING

Analysis of data for suspected and confirmed cases of snakebite collected prospectively by the Australian Snakebite Project, 2005-2019, from 200 hospitals across Australia.

PARTICIPANTS

1363 patients for whom D-dimer was quantitatively assessed within 24 hours of suspected or confirmed snakebite.

MAIN OUTCOME MEASURES: Diagnostic performance of quantitative D-dimer testing for detecting systemic envenoming with VICC (area under the receiver operating characteristic curve, AUC); optimal D-dimer cut-off value (maximum sum of sensitivity and specificity).

RESULTS

D-dimer values exceeded 2.5 mg/L within three hours of the bite for 95% of patients who developed VICC, and were lower than 2.5 mg/L for 95% of non-envenomed patients up to six hours after snakebite. The AUC for diagnosing envenoming with VICC on the basis of quantitative D-dimer testing within six hours of snakebite was 0.97 (95% CI, 0.96-0.98; 944 patients). Diagnostic performance increased during the first three hours after snakebite; for quantitative D-dimer testing at 2-6 hours, the AUC was 0.99 (95% CI, 0.99-1.0); with a cut-off of 2.5 mg/L, sensitivity was 97.1% (95% CI, 95.0-98.3%) and specificity 99.0% (95% CI, 97.6-99.6%) for VICC. For 36 patients with normal international normalised ratio (INR) and activated partial thromboplastin time (aPTT) values 2-6 hours after snakebite, the AUC was 0.97 (95% CI, 0.93-1.0); with a cut-off of 1.4 mg/L, sensitivity was 94% (95% CI, 82-99%) and specificity 96% (95% CI, 94-97%). In all but one of 84 patients who developed VICC-related acute kidney injury, D-dimer values exceeded 4 mg/L within 24 hours of the bite.

CONCLUSION

D-dimer concentrations assessed 2-6 hours after snakebite, with a cut-off value of 2.5 mg/L, could be useful for diagnosing envenoming with VICC.

Для цитирования: Isbister Geoffrey K, Noutsos Tina, Jenkins Shane, Isoardi Katherine Z, Soderstrom Jessamine, Buckley Nicholas A. D-dimer testing for early detection of venom-induced consumption coagulopathy after snakebite in Australia (ASP-29).. The Medical journal of Australia. 2022. DOI: 10.5694/mja2.51589.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.