Hypnosis for the control of pain associated with external cephalic version: a comparative study.
Аннотация
OBJECTIVE
To assess the effectiveness of hypnosis to reduce pain and facilitate external cephalic version (ECV).
DESIGN
Cohort study.
SETTING
Geneva University Hospitals, Switzerland.
PARTICIPANTS
63 women attempting ECV under hypnosis from 2010 to 2011 were compared with 122 women who received standard care from 2005 through 2008.
INTERVENTION: Immediately after the ECV attempt, both groups completed the same questionnaire evaluating the participants' pain (visual analogue and verbal rating scales) and experience with the procedure. Physicians also completed a questionnaire that elicited their views on the effect of hypnosis on the intervention. A chi-squared test was used to compare differences in proportions, and the Mann-Whitney U test was used for differences in continuous variables. A thematic content analysis of the obstetricians' responses to the open question regarding their experience of hypnotist accompaniment was also performed.
OUTCOME MEASURES: Pain evaluated by women (visual analogue and verbal rating scales) and success rate of ECV.
RESULTS
Pain intensity reported by women did not significantly differ between the hypnosis group and the standard care group (visual analogue scale score, 6.0 versus 6.3, respectively; p=.25; difference for verbal rating scale, p=0.31. In 72% of cases, physicians reported that hypnosis facilitated the procedure. The success rates in both groups were not significantly different (30% with hypnosis compared with 38% without; p=.31). Most women in both groups found the ECV attempt painful and a source of anxiety but would undergo it again if necessary.
CONCLUSION
Hypnosis accompaniment during ECV does not reduce pain intensity associated with the procedure or improve the probability of a successful version.