MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/ico.0b013e3181bd4bc1

Медицинская библиотека · Cornea · 2010

Multipurpose solutions and contact lens: modulation of cytotoxicity and apoptosis on the ocular surface.

Dutot Mélody, Reveneau Elisa, Pauloin Thierry, Fagon Roxane, Tanter Caroline, Warnet Jean-Michel, Rat Patrice

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: We evaluated (1) 4 multipurpose lens care solutions and 3 contact lenses (soft and rigid) for cytotoxicity according to ISO 10993-5 standard (medical device biocompatibility) and (2) the protective effects of a marine cationic solution and hyaluronic acid.

METHODS

Low water soft lens, high water soft lens, and rigid lens were laid on a conjunctival cell line after being soaked in multipurpose solution (Optifree Express, Renu, Solocare Aqua, or Menicare Plus). Cell morphology was microscopically observed, and cell viability was evaluated using the neutral red test. Apoptosis was assessed after direct contact of multipurpose solutions (MPS) with conjunctival cells using fluorescence microscopy and flow cytometry. The ability of a controlled ionization marine solution and hyaluronic acid to prevent multipurpose solution's cytotoxicity was finally evaluated.

RESULTS

Contact lenses soaked in the MPS induced cell morphology alterations and loss of cell viability. Rinsing the lens with the marine solution improved cell viability and preincubating cells with hyaluronic acid inhibited apoptosis.

CONCLUSIONS

MPS can be damaging for the ocular surface cells. We proposed to rinse the lens with a marine solution before insertion of the lens on the cornea to wash away the multipurpose solution and to use hyaluronic acid to protect the ocular surface cells against apoptosis induced by MPS.

Для цитирования: Dutot Mélody, Reveneau Elisa, Pauloin Thierry, Fagon Roxane, Tanter Caroline, Warnet Jean-Michel, Rat Patrice. Multipurpose solutions and contact lens: modulation of cytotoxicity and apoptosis on the ocular surface.. Cornea. 2010. DOI: 10.1097/ico.0b013e3181bd4bc1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.