MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ejrad.2026.112776

Медицинская библиотека · European journal of radiology · 2026

Image registration improves inter-reader agreement of objective response in CT assessment of pancreas adenocarcinoma.

Heiselman Jon S, Horvat Natally, El Homsi Maria, Agridag-Ucpinar Burcin, Yildirim Onur, Gonen Mithat, Ecker Brett L, O'Reilly Eileen M, Drebin Jeffrey A, Balachandran Vinod P, Kingham T Peter, Soares Kevin C, D'Angelica Michael I, Do Richard K G, Jarnagin William R, Wei Alice C, Chakraborty Jayasree

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

Pancreatic ductal adenocarcinoma (PDAC) exhibits ill-defined appearance on imaging during neoadjuvant therapy (NAT), which may limit consistency of dimensional measurements for objective response. This study evaluates inter-reader variability of current clinical measures of tumor size and interval response between baseline and restaging CT, and compares reader reliability with and without image registration assistance.

METHODS

Two senior and two junior radiologists retrospectively reviewed imaging of resectable PDAC patients enrolled in an IRB-approved Phase II clinical trial. Readers segmented lesion volumes from baseline and restaging CT and measured axial plane diameters to evaluate therapeutic response according to RECIST v1.1 and WHO criteria. Reliability of criteria index measures were compared with a computer-assisted image registration approach. Inter-reader agreements were quantified via generalized conformity index (GCI), concordance correlation coefficient (CCC), and Fleiss' Kappa (k). Statistical analyses were performed with significance level α = 0.05.

RESULTS

Baseline and restaging imaging of 30 patients (67 ± 10y, 50% female) were evaluated. Inter-reader agreements of segmented tumor volumes at baseline/restaging were low (junior: GCI = 0.42/0.35, CCC = 0.36/0.68; senior: GCI = 0.43/0.39, CCC = 0.62/0.96; all readers: GCI = 0.43/0.38, CCC = 0.66/0.78). Agreements in percent change in tumor size differed by experience level (longest diameter: CCC = 0.26/0.77/0.59, p < 0.01; diameter product: CCC = 0.32/0.86/0.66, p < 0.001) and produced low kappa agreements (RECIST: k = 0.0/0.37/0.23, p < 0.01; WHO: k = 0.0/0.31/0.18, p = 0.01 [junior/senior/all readers]). Image registration-assisted tumor response produced higher agreements across all levels of reader experience (k = 0.82/0.80/0.81, p < 0.01; CCC = 0.83/0.95/0.91, p < 0.05 [junior/senior/all readers]).

CONCLUSION

Substantial measurement variability exists in CT assessment of PDAC tumor response during NAT. Longitudinal image registration improves reproducibility and diminishes experience gap in radiologist assessments of objective response.

Для цитирования: Heiselman Jon S, Horvat Natally, El Homsi Maria, Agridag-Ucpinar Burcin, Yildirim Onur, Gonen Mithat, Ecker Brett L, O'Reilly Eileen M, Drebin Jeffrey A, Balachandran Vinod P, Kingham T Peter, Soares Kevin C, D'Angelica Michael I, Do Richard K G, Jarnagin William R, Wei Alice C, Chakraborty Jayasree. Image registration improves inter-reader agreement of objective response in CT assessment of pancreas adenocarcinoma.. European journal of radiology. 2026. DOI: 10.1016/j.ejrad.2026.112776.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.