DOI 10.1016/j.ejso.2021.10.026
BROWSE: A multicentre comparison of nine year outcomes in acellular dermal matrix based and complete submuscular implant-based immediate breast reconstruction-aesthetics, capsular contracture and patient reported outcomes.
Аннотация
UNLABELLED: Approximately 60% of implant-based breast reconstructions (IBBR) are performed with an acellular dermal matrix (ADM), for which, reliable, good quality long-term outcome data is limited. In a retrospective multicentre cohort study, we aimed to determine long-term aesthetic and quality of life outcomes of IBBR with ADM (Strattice™) compared to a submuscular technique.
METHODS
Capsular contracture (Baker III/IV capsule) was determined by clinical examination by an independent researcher. Quality of life was assessed using BREAST-Q and aesthetic outcome by photographic assessment from a breast surgeon, breast care nurse and lay person, blinded to reconstruction type.
RESULTS
We recruited 117 (51 bilateral) patients with ADM reconstructions, median follow-up 62 months (range 29-113) and 49 patients (16 bilateral) with submuscular reconstructions, median follow-up 76 months (range 38-111). 17 (10.1%) ADM reconstructions were Baker 3/4 compared to six (9.2%) submuscular (p = 0.85). Of the Baker 1/2 reconstructions six (3.6%) ADM and eight (13.6%) submuscular had previously undergone revision surgery to correct capsular contracture (p = 0.01). Combining both findings gave an estimated rate of capsular contracture of 13.6% in the ADM group and 21.2% in the submuscular (p = 0.14). A higher mean score for satisfaction with breasts was demonstrated when comparing ADM to submuscular (62 and 55, respectively; p = 0.01) but no significant difference in other BREAST-Q domains. The mean 'general satisfaction' score was higher in the ADM group for all three photograph assessors.
CONCLUSION
This study provides evidence of improved aesthetic outcome and reduction in capsular contracture with ADM reconstruction when compared to submuscular, consistent over long-term follow-up.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.