PURPOSE: To describe the incidence and outcome of retinal breaks in vitrectomy for retained lens fragments.

METHODS

This is a retrospective noncomparative interventional case series. Medical records of consecutive cases of vitrectomy for retained lens fragments over a period of 4 years were reviewed. Main outcome measures were incidence of breaks, visual acuity outcome, and occurrence of postoperative complications.

RESULTS

We included 89 consecutive cases in 89 patients. The median interval between cataract surgery and vitrectomy was 2 days (range, 0-106 days). Visual acuity at last follow-up was ≥ 0.5 in 70% of cases. During surgery, retinal breaks were found in 29% of cases. Induction of a posterior vitreous detachment, the use of a fragmatome, or delay between cataract surgery and vitrectomy did not influence retinal break incidence. Postoperative retinal detachment occurred in only 2% of cases. Other complications were intraoperative choroidal hemorrhage in 1 case, postoperative macular pucker in 2, postoperative macular edema in 1, and glaucoma in 2 cases.

CONCLUSION

We identified a high number of retinal breaks during vitrectomy for retained lens fragments. Prophylactic treatment of breaks and other areas of retinal traction seem to reduce the risk of postoperative retinal detachment.

Для цитирования: Tan H Stevie, Mura Marco, Oberstein Sarit Y Lesnik, Bijl Heico M. Retinal breaks in vitrectomy for retained lens fragments.. Retina (Philadelphia, Pa.). 2012. DOI: 10.1097/iae.0b013e3182576d46.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.