DOI 10.1016/j.jtcvs.2005.03.042
Ventricular constraint in dilated cardiomyopathy: a new, compliant textile mesh exerts prophylactic and therapeutic properties.
Аннотация
BACKGROUND
Dilated cardiomyopathy is associated with a progressive decrease in cardiac function, leading to end-stage heart failure. We aimed to stop this process by mechanically constraining the heart with a new, compliant textile mesh.
METHODS
In 16 male Munich minipigs (50 +/- 7 kg), dilated cardiomyopathy with congestive heart failure was induced through 4 weeks of rapid ventricular pacing (220 beats/min). In the early-mesh group (n = 8), a polyvinylidene fluoride mesh was positioned around both ventricles before pacing was started. In the other group (n = 8), experimental dilated cardiomyopathy through rapid pacing was induced (no mesh). After mesh grafting, rapid pacing was continued (late mesh).
RESULTS
Rapid pacing in the no-mesh group (control group) significantly decreased both systolic (cardiac output, peak systolic pressure, and the derivative of pressure increase [dP/dt(max)]) and diastolic (minimum rate of pressure rise [dP/dt(min)] and left ventricular end-diastolic pressure) variables, whereas these variables remained almost unchanged in the early-mesh group. In the late-mesh group the passive-elastic constraint not only prevented further deterioration but even exerted reverse remodeling to some extent (dP/dt(max) and left ventricular end-diastolic pressure, P < .05).
CONCLUSIONS
Ventricular constraint with the new mesh seems to be a prophylactic and therapeutic option in cardiac insufficiency caused by ventricular dilation. This passive-elastic cardioplasty induced reverse remodeling of dilated hearts and significantly improved diastolic and systolic ventricular function.