MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1067/mva.1992.40474

Медицинская библиотека · Journal of vascular surgery · 1992

Current use of inferior vena cava filters.

Magnant J G, Walsh D B, Juravsky L I, Cronenwett J L

СтатьяПеревод в очереди

Аннотация

To study possible changes in the clinical use of inferior vena cava (IVC) filters caused by the introduction of percutaneous delivery systems, we reviewed all patients who underwent placement of IVC filters at our institution from 1988 to 1991. Eighty-four patients (52 men and 32 women) ranging in age from 18 to 90 years (mean 67 years) were identified. Filters were required because of contraindications to anticogulation in 64% anticoagulation failure in 25%, and preoperative prophylaxis in 11% of patients. The underlying disease was lower extremity deep vein thrombosis in 50% and pulmonary embolism in 45% of patients. Five percent of patients received prophylactic filters without documented thromboembolism. All filters were placed percutaneously by interventional radiologists, 77 through the common femoral vein and 7 through the internal jugular vein. Three types of filters were used. One procedure-related death occurred because of acute IVC occlusion. Fatal pulmonary embolism within 48 hours after filter placement was documented in one patient and suspected in one late death. No other clinically apparent pulmonary embolism or leg swelling occurred after filter placement. Minor complications related to filter placement occurred in 13 patients, but none required operative intervention. Analysis of complication rates of the three filter types was precluded by the small sample size. After a mean follow-up of 11 months, 42 patients (50%) had died of malignancy (n = 25), multisystem organ failure (MSOF; n = 7), cardiovascular events (n = 4), recurrent pulmonary embolism (n = 2), cerebrovascular events (n = 4), or an unknown cause (n = 1). Twenty-three patients (27%) died before hospital discharge.(ABSTRACT TRUNCATED AT 250 WORDS)

Для цитирования: Magnant J G, Walsh D B, Juravsky L I, Cronenwett J L. Current use of inferior vena cava filters.. Journal of vascular surgery. 1992. DOI: 10.1067/mva.1992.40474.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.