MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1063/5.0342332

Медицинская библиотека · The Review of scientific instruments · 2026

Absolutely calibrated scintillator stack spectrometer for high-intensity laser-plasma experiments.

Agarwal S, Singh S, Devi P, Krupka M, Garcia A Laso, Chvatil D, Dudzak R, Krasa J, Juha L

СтатьяПеревод в очереди

Аннотация

Real-time online diagnostics are essential for high-repetition-rate laser-plasma experiments, offering clear advantages over traditional, manually exchanged offline detectors, such as imaging plates, by eliminating the shot-to-shot processing time. Scintillator based detectors are widely used to measure bremsstrahlung radiation from laser-matter interactions, enabling the characterization of hot-electron distributions. In this study, we present absolute calibration of a lutetium-yttrium oxyorthosilicate crystal-based multilayer scintillator stack spectrometer performed at the MT25 microtron facility in Prague. Bremsstrahlung radiation was generated by irradiating a tungsten converter with monoenergetic electron beams in the energy range between 5 MeV and 22 MeV. The response of the individual crystal was measured and compared with the energy deposition calculated using the Fluktuierende Kaskade (FLUKA) Monte Carlo simulation. A linear correlation between signal response and energy deposition was obtained for all crystals within the experimental uncertainty, confirming detector linearity with the calibration factor 0.014 ± 0.002 ADU/keV (where ADU denotes the analog-to-digital unit). This calibration enables quantitative, real-time measurement of bremsstrahlung spectra and is valuable for particle acceleration, high-intensity laser-plasma experiments, laboratory astrophysics, warm dense matter, and inertial confinement fusion studies.

Для цитирования: Agarwal S, Singh S, Devi P, Krupka M, Garcia A Laso, Chvatil D, Dudzak R, Krasa J, Juha L. Absolutely calibrated scintillator stack spectrometer for high-intensity laser-plasma experiments.. The Review of scientific instruments. 2026. DOI: 10.1063/5.0342332.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.