MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1021/acsmeasuresciau.6c00041

Медицинская библиотека · ACS measurement science au · 2026

A 3D Printed Mini-Gel Electrophoresis System for Rapid and Inexpensive DNA Nanoswitch Biosensing.

Morya Vinod, Hayden Andrew, Zhou Lifeng, Cole Dadrian, Halvorsen Ken

СтатьяПеревод в очереди

Аннотация

Gel electrophoresis has been a cornerstone laboratory technique for decades, yet it is often viewed as cumbersome and costly and confined to laboratory settings. Recent advances in DNA nanotechnology have used electrophoresis as a primary readout for some biosensing applications such as DNA nanoswitches, where a conformational change in a DNA structure indicates the presence of a target molecule. Conventional gel electrophoresis setups are not ideal for such targeted applications, with moderate equipment cost, excessive reagent use, and time-consuming processes. Here, we adopt a reductionist, application-driven approach to redesign gel electrophoresis specifically for DNA-nanoswitch-based detection. We present a fully 3D printable mini-gel electrophoresis system that incorporates conductive plastic electrodes, demonstrating performance comparable to conventional systems using platinum electrodes. By optimizing the interelectrode distance and running parameters, our system resolves the on/off states of DNA nanoswitches in as little as 1 min. We further show that the device operates reliably at low voltages, including when powered by a USB power bank, and even enables instrument-free nanoswitch readout using an LED with a cell phone camera. Our design substantially reduces the cost, voltage requirements, material usage, operational complexity, and experimental time. These improvements make gel-based biosensing more practical outside traditional laboratory environments, paving the way for the broader adoption of gel electrophoresis in point-of-care and resource-limited settings.

Для цитирования: Morya Vinod, Hayden Andrew, Zhou Lifeng, Cole Dadrian, Halvorsen Ken. A 3D Printed Mini-Gel Electrophoresis System for Rapid and Inexpensive DNA Nanoswitch Biosensing.. ACS measurement science au. 2026. DOI: 10.1021/acsmeasuresciau.6c00041.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.