MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1021/acs.analchem.6c03232

Медицинская библиотека · Analytical chemistry · 2026

Flexible Membrane-Integrated Zipper CHA Amplification for Rapid and Sensitive MicroRNA Detection.

Wang Bo, Li Wenmeng, Lu Gaoyang, Wen Jialin, Fan Jingwen, Wang Menghui, Wang Yin, Chen Chuangyi, Wen Mei, Chen Mei, Ke Guoliang, Zhang Xiao-Bing

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Catalytic hairpin assembly (CHA) is a widely employed signal amplification strategy for developing highly sensitive DNA biosensors, holding great promise for early disease diagnosis. However, conventional CHA systems often suffer from slow reaction kinetics, high nonspecific background signals, and limited stability in complex biological matrices. Inspired by the spatial confinement and fluidity of natural cell membranes, we herein report a red blood cell (RBC) membrane-anchored zipper-CHA system (RBC-ZCHA). In this system, preassembled low-background zipper-CHA probes (ZCHA) are anchored to the RBC membrane via cholesterol-modified DNA strands. This design synergistically enhances local probe concentration and intermolecular collision efficiency through multilevel confinement effects and dynamic membrane fluidity, thereby accelerating the reaction kinetics and improving detection sensitivity. Compared with the free-diffusion CHA system (Free-CHA), the RBC-ZCHA system exhibits lower background signals, accelerated reaction rates (approximately 5-fold increase), enhanced detection sensitivity (approximately 2 orders of magnitude higher), and superior stability in complex matrices. The designed system enables rapid and sensitive detection of microRNA in human serum, establishing a biocompatible and efficient platform for molecular diagnostics.

Для цитирования: Wang Bo, Li Wenmeng, Lu Gaoyang, Wen Jialin, Fan Jingwen, Wang Menghui, Wang Yin, Chen Chuangyi, Wen Mei, Chen Mei, Ke Guoliang, Zhang Xiao-Bing. Flexible Membrane-Integrated Zipper CHA Amplification for Rapid and Sensitive MicroRNA Detection.. Analytical chemistry. 2026. DOI: 10.1021/acs.analchem.6c03232.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.