MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1161/hypertensionaha.125.26209

Медицинская библиотека · Hypertension (Dallas, Tex. : 1979) · 2026

Development and Validation of the AI-HeartAge Model in Framingham and UK Biobank.

Korzinski Timothy J, Prescott Brenton R, Hamel-Sellman David J, Xanthakis Vanessa, Cooper Leroy L, Hamburg Naomi M, Tsao Connie W, Benjamin Emelia J, Vasan Ramachandran S, Mitchell Gary F

СтатьяВалидационное исследованиеПеревод в очереди

Аннотация

BACKGROUND

Arterial pressure waveform shape conveys information regarding interactions between the left ventricle and aorta that could provide an estimate of biological heart age and cardiovascular disease (CVD) risk.

METHODS

Artificial intelligence heart age (AI-HA) was estimated by averaging results from 2 convolutional neural networks trained to predict mitral annulus tissue Doppler e' and s' peak velocities using an uncalibrated arterial tonometry or photoplethysmography waveform as input. Models were developed using FHS (Framingham Heart Study) participant pressure waveforms and echocardiographic measurements (N=6916 participants, 38 174 waveforms, 56% women, mean age 61±12). We validated AI-HA using Cox modeling in an FHS holdout set of baseline radial waveforms (N=7018, 54% women, age 50±16 years) and in UK Biobank participants (N=67 986, 53% women, age 57±8 years).

RESULTS

In FHS (up to 10 years of follow-up, 148 heart failure [HF] and 331 CVD events), using models that adjusted for PREVENT (AHA Predicting Risk of CVD Events) risk factors, AI-HA was associated with incident HF (hazard ratio, 2.09 [CI, 1.64-2.68]; continuous net reclassification, 0.22 [CI, 0.13-0.30]) and CVD (hazard ratio, 1.52 [CI, 1.28-1.81]; continuous net reclassification, 0.13 [CI, 0.07-0.20]). In UK Biobank (up to 10 years of follow-up, 1408 HF and 2709 CVD events), AI-HA was associated with incident HF (hazard ratio, 1.23 [CI, 1.13-1.33]; continuous net reclassification, 0.09 [CI, 0.06-0.12]) and CVD (hazard ratio, 1.22 [CI, 1.15-1.30]; continuous net reclassification, 0.08 [CI, 0.06-0.09]).

CONCLUSIONS

AI-HA is a novel and accessible measure of left ventricle function and HF risk in community-based samples.

Для цитирования: Korzinski Timothy J, Prescott Brenton R, Hamel-Sellman David J, Xanthakis Vanessa, Cooper Leroy L, Hamburg Naomi M, Tsao Connie W, Benjamin Emelia J, Vasan Ramachandran S, Mitchell Gary F. Development and Validation of the AI-HeartAge Model in Framingham and UK Biobank.. Hypertension (Dallas, Tex. : 1979). 2026. DOI: 10.1161/hypertensionaha.125.26209.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.