MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1159/000550005

Медицинская библиотека · Cerebrovascular diseases (Basel, Switzerland) · 2025

Digital Health-Enabled Monitoring Strategies for Atrial Fibrillation Detection after Embolic Stroke of Undetermined Source: A Cost-Effectiveness Analysis of Implantable Loop Recorders, Wearable Devices, and Usual Care.

Boettger Priyanka, Matetic Andrija, Piayda Kerstin, Juenemann Martin, Lemm Henning, Tükenmez Engin, Buerke Michael, Omar Omar Alhaj

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

Embolic stroke of undetermined source (ESUS) is frequently attributable to atrial fibrillation (AF), yet remains undetected when episodes are brief or asymptomatic. Digital health-enabled cardiac monitoring offers novel pathways for secondary prevention. Implantable loop recorders (ILRs) provide continuous long-term rhythm surveillance, while wearable electrocardiogram (ECG) devices offer greater accessibility but with uncertain diagnostic yield and economic value. We evaluated the cost-effectiveness of ILR versus wearable AF monitoring and usual care in ESUS.

METHODS

A cohort-based Markov model simulated 1,000 ESUS patients (mean age 65 years) over a 10-year horizon from the German statutory health insurance perspective. Clinical inputs included AF detection rates (ILR: 15-25%; wearables: 5-10%), risk reduction in ischemic stroke with oral anticoagulation (OAC), and mortality/disability utilities. Costs (EUR 2,024, 3% discount) captured device acquisition, implantation, follow-up, stroke care, and OAC therapy. Outcomes included incremental cost-effectiveness ratio (ICER) and incremental net monetary benefit at willingness-to-pay thresholds of EUR 20,000, EUR 30,000, and EUR 50,000/quality-adjusted life-year (QALY). Deterministic and probabilistic sensitivity analyses, including expected value of perfect information (EVPI), were performed.

RESULTS

ILR yielded 0.23 additional QALYs compared with wearables at an incremental cost of EUR 2,160, resulting in a base-case ICER of EUR 9,391/QALY. In a high-risk subgroup, the ICER decreased to EUR 5,520/QALY. Probabilistic analysis demonstrated >90% probability of cost-effectiveness at EUR 30,000/QALY, with moderate EVPI. These findings align with meta-analytic evidence (RR 3.88 for AF detection; RR 0.75 for stroke reduction) and indicate that prolonged monitoring (≥12 months) maximizes yield.

CONCLUSION

Digital health-enabled ILR monitoring is likely cost-effective for AF detection after ESUS, particularly in high-risk patients. Wearables may serve as an adjunct but deliver lower value. Results support targeted ILR implementation in post-ESUS care pathways and integration into digital health-driven guideline and reimbursement frameworks.

Для цитирования: Boettger Priyanka, Matetic Andrija, Piayda Kerstin, Juenemann Martin, Lemm Henning, Tükenmez Engin, Buerke Michael, Omar Omar Alhaj. Digital Health-Enabled Monitoring Strategies for Atrial Fibrillation Detection after Embolic Stroke of Undetermined Source: A Cost-Effectiveness Analysis of Implantable Loop Recorders, Wearable Devices, and Usual Care.. Cerebrovascular diseases (Basel, Switzerland). 2025. DOI: 10.1159/000550005.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.