Heterogeneity in HeartMate 3 implanting center infection management reveals opportunities for quality improvement and best practice initiatives during left ventricular assist device support.

Cowger Jennifer A, Schettle Sarah, Pagani Francis D, Sheikh Farooq H, Hajj Jennifer M, Barn Kulpreet, Kirklin James K, Singletary Brandon, Molina Ezequiel J, Soltesz Edward, Byku Mirnela, Daneshmand Mani, Uriel Nir, Coyle Laura, Wood Katherine L, O'Connell Kelly, Kormos Robert, Kanwar Manreet K

СтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

BACKGROUND

There is marked variability in device-related (DR) infection frequencies across HeartMate 3 (HM3) centers. The goal is to correlate center driveline (DL) management and infection mitigation practices with DR-infection development, laying foundation for development of best practice recommendations for one facet of HM3 patient care.

METHODS

Coordinators at 30 HM3 centers were surveyed about center practices for infection prophylaxis, intraoperative DL placement and postoperative care, and infection mitigation. Early (≤90 days) and late (>90 day) center DR-infection frequencies were calculated from Society of Thoracic Surgeons Intermacs data linkage. Correlations between center practice patterns and incident DR-infection were examined with multivariable Cox modeling (clustering adjusted hazard ratio [aHR]).

RESULTS

Within Intermacs (3,725 patients), 1-year freedom from DR-infection was 87% (80.6-87.3%). Initially, DL dressing changes were performed daily, weekly, and variably at 48%, 21% and 31% of centers. After 4 weeks, 57% deescalated dressing changes to weekly. Chlorhexidine cleanser with a silver-impregnated dressing (Chl-Sil) was standard at 52.7% of programs; 47.3% used chlorhexidine alone or other supplies. Use of Chl-Sil was associated with reduced early (aHR 0.48, p=0.004) and late (aHR 0.64, p=0.02) DR-infection while frequent dressing changes conferred higher late DR-infection (aHR 1.4, p=0.05). Antibiotic prophylaxis, DL tunneling, and diabetes practices did not correlate with DR-infection.

CONCLUSIONS

Given the burden of DR-infections, best practice recommendations are needed to standardize care. Application of Chl-Sil DL dressings could be a first step in achieving care standardization, while frequent dressing changes following DL incorporation should be avoided.

Для цитирования: Cowger Jennifer A, Schettle Sarah, Pagani Francis D, Sheikh Farooq H, Hajj Jennifer M, Barn Kulpreet, Kirklin James K, Singletary Brandon, Molina Ezequiel J, Soltesz Edward, Byku Mirnela, Daneshmand Mani, Uriel Nir, Coyle Laura, Wood Katherine L, O'Connell Kelly, Kormos Robert, Kanwar Manreet K. Heterogeneity in HeartMate 3 implanting center infection management reveals opportunities for quality improvement and best practice initiatives during left ventricular assist device support.. The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation. 2025. DOI: 10.1016/j.healun.2025.07.024.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.