MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/ehjdh/ztaf010

Медицинская библиотека · European heart journal. Digital health · 2025

Evaluation of real-world application of cardiac implantable electronic device-based multi-sensor algorithm for heart failure management.

Llewellyn Jennifer, Goode Rachel, Kahn Matthew, Valsecchi Sergio, Rao Archana

СтатьяПеревод в очереди

Аннотация

AIMS: Remote monitoring of cardiac implantable electronic devices enables pre-emptive management of heart failure (HF) without additional patient engagement. The HeartLogic™ algorithm in implantable cardioverter defibrillators (ICDs) combines physiological parameters to predict HF events, facilitating earlier interventions. This study evaluated its diagnostic performance and resource implications within an HF management service.

METHODS AND

RESULTS

In a single-centre study, 212 patients with cardiac resynchronization therapy ICDs (CRT-Ds) were monitored for 12-months. During follow-up, 18 (8%) patients died, and 15 HF hospitalizations occurred in 13 (6%) patients. Outpatient visits totalled 37 in 34 (16%) patients. HeartLogic™ alerts occurred in 58% of patients, with 100% sensitivity for HF-related hospitalizations. The positive predictive value was 29% including only alerts associated with HF events, while it was 51% including HF events and explained alerts. Unexplained alert rate was 0.46 per patient-year. Clinical interventions, mainly medication adjustments, followed 82 alerts. Total management time was 257 h/year, equivalent to 0.57 full-time equivalents for managing 1000 CRT-D patients.

CONCLUSION

The integration of HeartLogic™ into routine care demonstrated its utility in optimizing HF management, improving healthcare resource allocation. The algorithm can enhance proactive patient management and provide holistic care within the existing healthcare infrastructure.

Для цитирования: Llewellyn Jennifer, Goode Rachel, Kahn Matthew, Valsecchi Sergio, Rao Archana. Evaluation of real-world application of cardiac implantable electronic device-based multi-sensor algorithm for heart failure management.. European heart journal. Digital health. 2025. DOI: 10.1093/ehjdh/ztaf010.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.