DOI 10.1016/j.jacep.2024.12.002

Медицинская библиотека · JACC. Clinical electrophysiology · 2025

Cardioverter-Defibrillator Implantation as a Risk Factor For Motor Vehicle Crash.

Staples John A, Daly-Grafstein Daniel, Robinson Isaac, Khan Mayesha, Hawkins Nathaniel M, Chan Herbert, Erdelyi Shannon, Steinberg Christian, Maclure K Malcolm, Krahn Andrew D, Brubacher Jeffrey R

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Limited empirical evidence informs fitness-to-drive recommendations after implantable cardioverter-defibrillator (ICD) implantation. Cohort designs can be deceptive because ICD recipients differ from control individuals and may temporarily cease driving after implantation.

OBJECTIVES

This study sought to generate evidence to inform medical driving restrictions after ICD implantation.

METHODS

We used population-based data to identify all drivers involved in a serious motor vehicle crash in British Columbia, Canada, from 1997 to 2019. Exposure was defined as ICD implantation in the 6 months before a crash. One analysis used a case-crossover design to control for relatively fixed individual characteristics like driving experience. Another analysis used a responsibility design to account for road exposure (miles of driving per week). Both analyses used logistic regression with adjustment for potential confounders.

RESULTS

In the case-crossover analysis of crash-involved ICD recipients, ICD implantation occurred in 212 of 3,299 precrash intervals and in 485 of 6,598 control intervals, suggesting no temporal association between ICD implantation and subsequent crash (6.4% vs 7.4%; adjusted OR [aOR]: 0.86; 95% CI: 0.71-1.03; P = 0.11). In the analysis of all crash-involved drivers with determinate crash responsibility, 14 of 22 drivers with recent ICD implantation and 532,741 of 1,035,433 drivers without recent ICD implantation were deemed responsible for their crash, suggesting no association between ICD implantation and crash responsibility (crude proportion responsible, 64% vs 51%; aOR: 2.20; 95% CI: 0.94-5.30; P = 0.08).

CONCLUSIONS

The 6-month interval after ICD implantation is not associated with increased odds of crash nor with increased likelihood of crash responsibility. Contemporary driving restrictions in the first weeks after ICD implantation appear to adequately mitigate the potential increase in crash risk.

Для цитирования: Staples John A, Daly-Grafstein Daniel, Robinson Isaac, Khan Mayesha, Hawkins Nathaniel M, Chan Herbert, Erdelyi Shannon, Steinberg Christian, Maclure K Malcolm, Krahn Andrew D, Brubacher Jeffrey R. Cardioverter-Defibrillator Implantation as a Risk Factor For Motor Vehicle Crash.. JACC. Clinical electrophysiology. 2025. DOI: 10.1016/j.jacep.2024.12.002.