MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/smtd.70877

Медицинская библиотека · Small methods · 2026

Pixelated Scintillator Arrays with Si-SiO2 Waveguiding Architecture for High-Resolution x-ray Imaging.

Li Xinlin, Liu Jiaxing, Wang Junxin, Mei Xiaodan, Li Junchun, Tong Guoqing, Liu Hongbang, Lin Tao

СтатьяПеревод в очереди

Аннотация

High spatial resolution and sensitivity are critical performance metrics for x-ray imaging systems. Traditional thick polycrystalline scintillators suffer from severe internal light scattering, which limits imaging resolution and low-dose detection capability. Here, we present a pixelated scintillation screen with a waveguide architecture based on a Si-SiO2 array (SOA) template, in which crystalline Cs5Cu3Cl6I2, a low-dimensional perovskite-like halide, is used as the scintillation medium. The low-refractive-index SiO2 layer enables total internal reflection (TIR) for vertical photon guidance, while the Si substrate provides both high x-ray transmittance and visible light absorption, effectively reducing optical crosstalk. Using a vacuum-assisted infiltration process, Cs5Cu3Cl6I2 is infiltrated and recrystallized within the SOA channels, yielding a well-confined scintillator structure that suppresses lateral scattering and enhances vertical photon transport. Compared to conventional film-based scintillators, the SOA-based design exhibits markedly improved imaging performance, achieving a spatial resolution of 20.10 lp·mm-1 and a minimum detectable dose of 35 nGy·s-1. In addition, the fabrication process is highly scalable, allowing flexible construction of scintillator arrays with tailored pixel sizes and layouts. This approach provides a promising strategy for next-generation x-ray imaging with simultaneously high resolution and low-dose sensitivity.

Для цитирования: Li Xinlin, Liu Jiaxing, Wang Junxin, Mei Xiaodan, Li Junchun, Tong Guoqing, Liu Hongbang, Lin Tao. Pixelated Scintillator Arrays with Si-SiO2 Waveguiding Architecture for High-Resolution x-ray Imaging.. Small methods. 2026. DOI: 10.1002/smtd.70877.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.