Ziegler Betiana Michelle, Abelleyro Miguel Martín, Villegas María Emilia, Loria Julián Sanchez, Cifuentes Héctor Martín, Neme Daniela, Sciuccati Gabriela, Cervio Carolina, Arrieta Verónica, Listello Viviana, Cruz María Sol, Erro María Gabriela, Sánchez-Luceros Analía, De Brasi Carlos Daniel, Radic Claudia Pamela, Rossetti Liliana Carmen

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

Haemophilia B (HB) associates with deleterious variants in F9. HB management with FIX-concentrate infusions may be ineffective in 3%-9% patients who develop FIX-inhibitors.

AIM: To present our HB-series (n = 136) including all Argentinean patients with FIX-inhibitors (n = 13). To estimate F9-genotype-associated FIX-inhibitor risks from our series (GMH), and HB-international databases, FIX-UCL and EAHAD.

METHODS

F9-genotyping was performed by conventional protocols; or by short-read-NGS on a new F9-panel. FIX-inhibitor risks were estimated by case(inh+)/control(inh-) studies using OR(95%CI).

RESULTS

The spectrum of F9-genotypes from our GMH-series resulted similar to the one compiled in international databases, prevailing missense (45%), and nonsense (21%) in severe-HB and missense defects (> 80%) in non-severe-HB. Our set of HB-patients with FIX-inhibitors mostly included large-deletions and nonsense mutations, and 38.5% developed allergic reactions. Case/Control studies mainly aligned FIX-inhibitor risks in all three datasets. Considering severe-HB in GMH(n = 91)//FIX-UCL(n = 349)//EAHAD(n = 590), we observed a high-risk group that comprised entire-F9-deletions with highly-significant ORs of 24//12//35, all-large-deletions, 7//7//17 and nonsense mutations, 3//3//2; and a low-risk group confined to missense F9-variants with highly-significant protective ORs, 0.04//0.11//0.03, whilst other F9-variants did not differ from the null-hypothesis. Equal analysis from all-severities HB patients closely agreed with these results. An analysis of NS and FIX-inhibitor risks suggested the involvement of nonsense-mediated decay (NMD) in F9: nonsense (F9-exons_1-7) vs nonsense (F9-exon_8) resulted in highly-significantly incremented risks in both FIX-UCL(n = 124)//EAHAD(n = 171), ORs of 4(2-9)//4(3-6).

CONCLUSION

Our study provides robust estimations of F9-genotype-associated FIX-inhibitor risks in HB-patients and exposed the involvement of NMD.

Для цитирования: Ziegler Betiana Michelle, Abelleyro Miguel Martín, Villegas María Emilia, Loria Julián Sanchez, Cifuentes Héctor Martín, Neme Daniela, Sciuccati Gabriela, Cervio Carolina, Arrieta Verónica, Listello Viviana, Cruz María Sol, Erro María Gabriela, Sánchez-Luceros Analía, De Brasi Carlos Daniel, Radic Claudia Pamela, Rossetti Liliana Carmen. The Analysis of the FIX-inhibitor Risks Associated With the F9 Genotype in Patients With Haemophilia B Exposes the Involvement of Nonsense Mediated-decay: Argentinean and International Series.. Haemophilia : the official journal of the World Federation of Hemophilia. 2026. DOI: 10.1111/hae.70356.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.