Motor vehicle crash risk after cardioverter-defibrillator implantation: a population-based cohort study.

Staples John A, Daly-Grafstein Daniel, Robinson Isaac, Khan Mayesha, Erdelyi Shannon, Hawkins Nathaniel M, Chan Herbert, Steinberg Christian, Chakrabarti Santabhanu, Krahn Andrew D, Brubacher Jeffrey R

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Limited empirical evidence informs driving restrictions after implantable cardioverter-defibrillator (ICD) implantation. We sought to evaluate real-world motor vehicle crash risks after ICD implantation.

METHODS

We performed a retrospective cohort study using 22 years of population-based health and driving data from British Columbia, Canada (2019 population: 5 million). Individuals with a first ICD implantation between 1997 and 2019 were age and sex matched to three controls. The primary outcome was involvement as a driver in a crash that was attended by police or that resulted in an insurance claim. We used survival analysis to compare crash risk in the first 6 months after ICD implantation to crash risk during a corresponding 6-month interval among controls.

RESULTS

A crash occurred prior to a censoring event for 296 of 9373 individuals with ICDs and for 1077 of 28 119 controls, suggesting ICD implantation was associated with a reduced risk of subsequent crash (crude incidence rate, 8.5 vs 10.5 crashes per 100 person-years; adjusted HR (aHR), 0.71; 95% CI 0.61 to 0.83; p<0.001). Results were similar after stratification by primary versus secondary prevention ICD. Relative to controls, ICD patients had more traffic contraventions in the 3 years prior to ICD implantation but fewer contraventions in the 6 months after implantation, suggesting individuals reduced their road exposure (hours or miles driven per week) or drove more conservatively after ICD implantation.

CONCLUSIONS

Crash risk is lower in the 6 months after ICD implantation than among matched controls, likely because individuals reduced their road exposure in order to comply with contemporary postimplantation driving restrictions. Policymakers might consider liberalisation of postimplantation driving restrictions while monitoring crash rates.

Для цитирования: Staples John A, Daly-Grafstein Daniel, Robinson Isaac, Khan Mayesha, Erdelyi Shannon, Hawkins Nathaniel M, Chan Herbert, Steinberg Christian, Chakrabarti Santabhanu, Krahn Andrew D, Brubacher Jeffrey R. Motor vehicle crash risk after cardioverter-defibrillator implantation: a population-based cohort study.. Heart (British Cardiac Society). 2024. DOI: 10.1136/heartjnl-2024-324541.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.