MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.resuscitation.2024.110386

Медицинская библиотека · Resuscitation · 2024

The factors associated with the provision of public access defibrillation in Japan - A nationwide cohort study.

Nakagawa Koshi, Sagisaka Ryo, Morioka Daigo, Kimura Ryu, Kijima Hinata, Tanaka Hideharu

СтатьяПеревод в очереди

Аннотация

AIM: The association between out-of-hospital cardiac arrest (OHCA) and the appropriate provision of public access defibrillation (PAD) remains unclear. This study aimed to evaluate the factors associated with whether or not PAD was provided.

METHODS

This retrospective cohort study utilized the All-Japan Utstein and Emergency Transport Registries in 2021. We included OHCA patients who were applied to automated external defibrillators (AEDs) by bystanders and were deemed eligible for defibrillation by an AED. We defined PAD provided or no PAD provided based on bystander defibrillation. Multivariable logistic regression analysis with the Firth bias adjustment method was employed to estimate the adjusted odds ratios (AORs) and 95% confidence intervals (CIs) for the exploratory evaluation of factors associated with PAD provided.

RESULTS

1949 patients were eligible for analysis (PAD provided, n = 1696 [87.0%]; no PAD provided, n = 253 [13.0%]). Factors positively associated with PAD provided were male (AOR [95% CI], 1.61 [1.17-2.21]; vs. female), other public place incidence (AOR [95% CI], 10.65 [1.40-1367.54]; vs. public place), non-family member witnessed (AOR [95% CI], 2.51 [1.86-3.42]; vs. unwitnessed) and conventional cardiopulmonary resuscitation (CPR), (AOR [95% CI], 1.75 [1.17-2.67]; vs. hands-only CPR). Conversely, factors negatively associated with no PAD provided were over 65 years old (AOR [95% CI], 0.48 [0.28-0.80]; vs. 19-64 yr), night-time onset (AOR [95% CI], 0.61 [0.45-0.83]; vs. daytime), non-cardiogenic (AOR [95% CI], 0.43 [0.31-0.61]; vs. cardiogenic), home setting (AOR [95% CI], 0.33 [0.14-0.83]; vs. public place), healthcare facility setting (AOR [95% CI], 0.40 [0.23-0.66]; vs. public place), no bystander CPR (AOR [95% CI], 0.31 [0.14-0.71]; vs. hands-only CPR), and dispatcher-assistance (AOR [95% CI], 0.72 [0.53-0.97]; vs. no dispatcher-assistance).

CONCLUSION

Male patients, other public place onset, witnessed by non-family and conventional CPR were associated with PAD provide. Therefore, training skilled first responders to use AEDs appropriately is necessary.

Для цитирования: Nakagawa Koshi, Sagisaka Ryo, Morioka Daigo, Kimura Ryu, Kijima Hinata, Tanaka Hideharu. The factors associated with the provision of public access defibrillation in Japan - A nationwide cohort study.. Resuscitation. 2024. DOI: 10.1016/j.resuscitation.2024.110386.