DOI 10.1016/j.cardfail.2024.03.011
Association of Psychosocial Risk Factors With Quality of Life and Readmissions 1 Year After LVAD Implantation.
Аннотация
BACKGROUND
Among patients with advanced heart failure (HF), treatment with a left ventricular assist device (LVAD) improves health-related quality of life (HRQOL). We investigated the association between psychosocial risk factors, HRQOL and outcomes after LVAD implantation.
METHODS
A retrospective cohort (n = 9832) of adults aged ≥ 19 years who received durable LVADs between 2008 and 2017 was identified by using the Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS). Patients were considered to have psychosocial risk factors if ≥ 1 of the following were present: (1) substance abuse; (2) limited social support; (3) limited cognitive understanding; (4) repeated nonadherence; and (5) major psychiatric disease. Multivariable logistic and linear regression models were used to evaluate the association between psychosocial risk factors and change in Kansas City Cardiomyopathy Questionnaire (KCCQ)-12 scores from baseline to 1 year, persistently poor HRQOL (KCCQ-12 score < 45 at baseline and 1 year), and 1-year rehospitalization.
RESULTS
Among the final analytic cohort, 2024 (20.6%) patients had ≥ 1 psychosocial risk factors. Psychosocial risk factors were associated with a smaller improvement in KCCQ-12 scores from baseline to 1 year (mean ± SD, 29.1 ± 25.9 vs 32.6 ± 26.1; P = 0.015) for a difference of -3.51 (95% confidence interval [CI]: -5.88 to -1.13). Psychosocial risk factors were associated with persistently poor HRQOL (adjusted odds ratio [aOR] 1.35, 95% confidence interval [CI] 1.04-1.74), and 1-year all-cause readmission (adjusted hazard ratio [aHR] 1.11, 95% CI 1.05-1.18). Limited social support, major psychiatric disorder and repeated nonadherence were associated with persistently poor HRQOL, while major psychiatric disorder was associated with 1-year rehospitalization.
CONCLUSION
The presence of psychosocial risk factors is associated with lower KCCQ-12 scores and higher risk for readmission at 1 year after LVAD implantation. These associations are statistically significant, but further research is needed to determine whether these differences are clinically meaningful.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.