Incompleteness of health-related quality of life assessments before left ventricular assist device implant: A novel quality metric.

Yang Guangyu, Zhang Min, Zhou Shiwei, Hou Hechuan, Grady Kathleen L, Stewart James W, Chenoweth Carol E, Aaronson Keith D, Fetters Michael D, Chandanabhumma P Paul, Pienta Michael J, Malani Preeti N, Hider Ahmad M, Cabrera Lourdes, Pagani Francis D, Likosky Donald S, Michigan Congestive Heart Failure Investigators

СтатьяПоддержка исследования: вне правительства СШАПоддержка службы здравоохранения СШАПеревод в очереди

Аннотация

BACKGROUND

Improved health-related quality of life (HRQOL) is an important outcome following durable left ventricular assist device (LVAD) implant. However, half of pre-implant HRQOL data are incomplete in The Society of Thoracic Surgeons' Intermacs registry. Pre-implant HRQOL incompleteness may reflect patient status or hospital resources to capture HRQOL data. We hypothesized that pre-implant HRQOL incompleteness predicts 90 day outcomes and serves as a novel quality metric.

METHODS

Risk factors for pre-implant HRQOL (EQ-5D-5L visual analog scale; 12-item Kansas City Cardiomyopathy Questionnaire "KCCQ") incompleteness were examined by stepwise logistic modeling. Direct standardization method was used to calculate adjusted incompleteness rates using a mixed effects logistic model. Hospitals were dichotomized as low or high based on median adjusted incompleteness rates. Andersen-Gill models were used to associate pre-implant HRQOL adjusted incompleteness rate with adverse events within 90 day post-implant.

RESULTS

The study cohort included 14,063 patients receiving a primary LVAD (4/2012-8/2017). HRQOL incompleteness at high-rate hospitals was more often due to administrative reasons (risk difference, EQ-5D: 10.1%; KCCQ-12: 11.6%) and less likely due to patient reasons (risk difference, EQ-5D: -8.9%; KCCQ-12: -11.4%). A 10% increase in the adjusted pre-implant EQ-5D incompleteness rate was significantly associated with higher risk of infection-related mortality (HR: 1.09), infection (HR: 1.05), and renal dysfunction (HR: 1.03). A 10% increase in the adjusted pre-implant KCCQ-12 incompleteness rate was significantly associated with higher risk of infection (HR: 1.04).

CONCLUSIONS

Hospital adjusted pre-implant HRQOL incompleteness was predictive of 90-day post-implant outcomes and may serve as a novel quality metric.

Для цитирования: Yang Guangyu, Zhang Min, Zhou Shiwei, Hou Hechuan, Grady Kathleen L, Stewart James W, Chenoweth Carol E, Aaronson Keith D, Fetters Michael D, Chandanabhumma P Paul, Pienta Michael J, Malani Preeti N, Hider Ahmad M, Cabrera Lourdes, Pagani Francis D, Likosky Donald S, Michigan Congestive Heart Failure Investigators. Incompleteness of health-related quality of life assessments before left ventricular assist device implant: A novel quality metric.. The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation. 2022. DOI: 10.1016/j.healun.2022.07.001.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.