Age-related differences and associated mid-term outcomes of subcutaneous implantable cardioverter-defibrillators: A propensity-matched analysis from a multicenter European registry.

Gulletta Simone, Gasperetti Alessio, Schiavone Marco, Vogler Julia, Fastenrath Fabian, Breitenstein Alexander, Laredo Mikael, Palmisano Pietro, Mitacchione Gianfranco, Compagnucci Paolo, Kaiser Lukas, Hakmi Samer, Angeletti Andrea, De Bonis Silvana, Picarelli Francesco, Arosio Roberto, Casella Michela, Steffel Jan, Fierro Nicolai, Guarracini Fabrizio, Santini Luca, Pignalberi Carlo, Piro Agostino, Lavalle Carlo, Pisanò Ennio, Viecca Maurizio, Curnis Antonio, Badenco Nicolas, Ricciardi Danilo, Dello Russo Antonio, Tondo Claudio, Kuschyk Jürgen, Della Bella Paolo, Biffi Mauro, Forleo Giovanni B, Tilz Roland

СтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

BACKGROUND

A few limited case series have shown that the subcutaneous implantable cardioverter-defibrillator (S-ICD) system is safe for teenagers and young adults, but a large-scale analysis currently is lacking.

OBJECTIVES

The purpose of this study was to compare mid-term device-associated outcomes in a large real-world cohort of S-ICD patients, stratified by age at implantation.

METHODS

Two propensity-matched cohorts of teenagers + young adults (≤30 years old) and adults (>30 years old) were retrieved from the ELISIR Registry. The primary outcome was the comparison of inappropriate shock rate. Complications, freedom from sustained ventricular arrhythmias, and overall and cardiovascular mortality were deemed secondary outcomes.

RESULTS

Teenagers + young adults represented 11.0% of the entire cohort. Two propensity-matched groups of 161 patients each were used for the analysis. Median follow-up was 23.1 (13.2-40.5) months. In total, 15.2% patients experienced inappropriate shocks, and 9.3% device-related complications were observed, with no age-related differences in inappropriate shocks (16.1% vs 14.3%; P = .642) and complication rates (9.9% vs 8.7%; P = .701). At univariate analysis, young age was not associated with increased rates of inappropriate shocks (hazard ratio [HR] 1.204 [0.675-2.148]: P = .529). At multivariate analysis, use of the SMART Pass algorithm was associated with a strong reduction in inappropriate shocks (adjusted HR 0.292 [0.161-0.525]; P <.001), whereas arrhythmogenic right ventricular cardiomyopathy (ARVC) was associated with higher rates of inappropriate shocks (adjusted HR 2.380 [1.205-4.697]; P = .012).

CONCLUSION

In a large multicenter registry of propensity-matched patients, use of the S-ICD in teenagers/young adults was safe and effective. The rates of inappropriate shocks and complications between cohorts were not significantly different. The only predictor of increased inappropriate shocks was a diagnosis of ARVC.

Для цитирования: Gulletta Simone, Gasperetti Alessio, Schiavone Marco, Vogler Julia, Fastenrath Fabian, Breitenstein Alexander, Laredo Mikael, Palmisano Pietro, Mitacchione Gianfranco, Compagnucci Paolo, Kaiser Lukas, Hakmi Samer, Angeletti Andrea, De Bonis Silvana, Picarelli Francesco, Arosio Roberto, Casella Michela, Steffel Jan, Fierro Nicolai, Guarracini Fabrizio, Santini Luca, Pignalberi Carlo, Piro Agostino, Lavalle Carlo, Pisanò Ennio, Viecca Maurizio, Curnis Antonio, Badenco Nicolas, Ricciardi Danilo, Dello Russo Antonio, Tondo Claudio, Kuschyk Jürgen, Della Bella Paolo, Biffi Mauro, Forleo Giovanni B, Tilz Roland. Age-related differences and associated mid-term outcomes of subcutaneous implantable cardioverter-defibrillators: A propensity-matched analysis from a multicenter European registry.. Heart rhythm. 2022. DOI: 10.1016/j.hrthm.2022.02.029.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.