MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1161/circheartfailure.121.008797

Медицинская библиотека · Circulation. Heart failure · 2021

Quantifying Benefit-Risk Preferences for Heart Failure Devices: A Stated-Preference Study.

Reed Shelby D, Yang Jui-Chen, Rickert Timothy, Johnson F Reed, Gonzalez Juan Marcos, Mentz Robert J, Krucoff Mitchell W, Vemulapalli Sreekanth, Adamson Philip B, Gebben David J, Rincon-Gonzalez Liliana, Saha Anindita, Schaber Daniel, Stein Kenneth M, Tarver Michelle E, Bruhn-Ding Dean

СтатьяПоддержка исследования: вне правительства СШАПоддержка службы здравоохранения СШАПеревод в очереди

Аннотация

BACKGROUND

Regulatory and clinical decisions involving health technologies require judgements about relative importance of their expected benefits and risks. We sought to quantify heart-failure patients' acceptance of therapeutic risks in exchange for improved effectiveness with implantable devices.

METHODS

Individuals with heart failure recruited from a national web panel or academic medical center completed a web-based discrete-choice experiment survey in which they were randomized to one of 40 blocks of 8 experimentally controlled choice questions comprised of 2 device scenarios and a no-device scenario. Device scenarios offered an additional year of physical functioning equivalent to New York Heart Association class III or a year with improved (ie, class II) symptoms, or both, with 30-day mortality risks ranging from 0% to 15%, in-hospital complication risks ranging from 0% to 40%, and a remote adjustment device feature. Logit-based regression models fit participants' choices as a function of health outcomes, risks and remote adjustment.

RESULTS

Latent-class analysis of 613 participants (mean age, 65; 49% female) revealed that two-thirds were best represented by a pro-device, more risk-tolerant class, accepting up to 9% (95% CI, 7%-11%) absolute risk of device-associated mortality for a one-year gain in improved functioning (New York Heart Association class II). Approximately 20% were best represented by a less risk-tolerant class, accepting a maximum device-associated mortality risk of 3% (95% CI, 1%-4%) for the same benefit. The remaining class had strong antidevice preferences, thus maximum-acceptable risk was not calculated.

CONCLUSIONS

Quantitative evidence on benefit-risk tradeoffs for implantable heart-failure device profiles may facilitate incorporating patients' views during product development, regulatory decision-making, and clinical practice.

Для цитирования: Reed Shelby D, Yang Jui-Chen, Rickert Timothy, Johnson F Reed, Gonzalez Juan Marcos, Mentz Robert J, Krucoff Mitchell W, Vemulapalli Sreekanth, Adamson Philip B, Gebben David J, Rincon-Gonzalez Liliana, Saha Anindita, Schaber Daniel, Stein Kenneth M, Tarver Michelle E, Bruhn-Ding Dean. Quantifying Benefit-Risk Preferences for Heart Failure Devices: A Stated-Preference Study.. Circulation. Heart failure. 2021. DOI: 10.1161/circheartfailure.121.008797.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.