Racial Differences in the Incidence and Impact of Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Replacement.

Park Hanbit, Ahn Jung-Min, Kang Do-Yoon, Kim Juyong Brian, Yeung Alan C, Nishi Takeshi, Fearon William F, Cantey Eric Page, Flaherty James D, Davidson Charles J, Malaisrie S Christopher, Kim Sehee, Yun Sung-Cheol, Ko Euihong, Lee Seung-Ah, Kim Dae-Hee, Kim Ho Jin, Kim Joon Bum, Choo Suk Jung, Park Duk-Woo, Park Seung-Jung

СтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVES

The aim of this study was to compare the incidence and prognostic significance of prosthesis-patient mismatch (PPM) after transcatheter aortic valve replacement (TAVR) according to racial groups.

BACKGROUND

PPM after TAVR may be of more concern in Asian populations considering their relatively small annular and valve sizes compared with Western populations.

METHODS

TP-TAVR (Transpacific TAVR Registry) was an international multicenter cohort study of patients with severe aortic stenosis who underwent TAVR in the United States and South Korea from January 2015 to November 2019. PPM was defined as moderate (0.65-0.85 cm2/m2) or severe (<0.65 cm2/m2) at the indexed effective orifice area. The primary outcome was a composite of death, stroke, or rehospitalization at 1 year.

RESULTS

Among 1,101 eligible patients (533 Asian and 569 non-Asian), the incidence of PPM was significantly lower in the Asian population (33.6%; moderate, 26.5%; severe, 7.1%) than in the non-Asian population (54.5%; moderate, 29.8%; severe, 24.7%). The 1-year rate of the primary outcome was similar between the PPM and non-PPM groups (27.5% vs 28.1%; P = 0.69); this pattern was consistent between Asian (25.4% vs 25.2%; P = 0.31) and non-Asian (28.7% vs 32.1%; P = 0.97) patients. After multivariable adjustment, the risk for the primary outcome did not significantly differ between the PPM and non-PPM groups in the overall population (HR: 0.95; 95% CI: 0.74-1.21), in Asian patients (HR: 1.07; 95% CI: 0.74-1.55), and in non-Asian patients (HR: 0.86; 95% CI: 0.63-1.19).

CONCLUSIONS

In this study of patients with severe aortic stenosis who underwent TAVR, the incidence of PPM was significantly lower in Asian patients than in non-Asian patients. The 1-year risk for the primary composite outcome was similar between the PPM and non-PPM groups regardless of racial group. (Transpacific TAVR Registry [TP-TAVR]; NCT03826264).

Для цитирования: Park Hanbit, Ahn Jung-Min, Kang Do-Yoon, Kim Juyong Brian, Yeung Alan C, Nishi Takeshi, Fearon William F, Cantey Eric Page, Flaherty James D, Davidson Charles J, Malaisrie S Christopher, Kim Sehee, Yun Sung-Cheol, Ko Euihong, Lee Seung-Ah, Kim Dae-Hee, Kim Ho Jin, Kim Joon Bum, Choo Suk Jung, Park Duk-Woo, Park Seung-Jung. Racial Differences in the Incidence and Impact of Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Replacement.. JACC. Cardiovascular interventions. 2021. DOI: 10.1016/j.jcin.2021.08.038.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.