DOI 10.1016/j.healun.2021.09.016
Impact of using higher-risk donor hearts for candidates with pre-transplant mechanical circulatory support.
Аннотация
BACKGROUND
We evaluated post-heart transplant (HTx) outcomes after use of higher-risk donor hearts for candidates supported with pre-HTx mechanical circulatory support (MCS).
METHODS
In this retrospective analysis of the national United Network for Organ Sharing registry, a total of 9,915 adult candidates on MCS underwent HTx from January 1, 2010 to March 31, 2019. Multi-organ, re-transplant, and congenital heart disease patients were excluded. Higher-risk donor organs met at least one of the following criteria: left ventricular ejection fraction <50%, donor to recipient predicted heart mass ratio <0.86, donor age >55 years, or ischemic time >4 hours. Primary outcome was 1 year post-transplant survival.
RESULTS
Among HTx recipients, 3688 (37.2%) received higher-risk donor hearts. Candidates supported with pre-HTx extracorporeal membrane oxygenation or biventricular assist device (n = 374, 3.8%) who received higher-risk donor hearts had comparable 1 year survival (HR: 1.14, 95% CI: [0.67-1.93], p = 0.64) to recipients of standard-risk donor hearts, when adjusted for recipient age and sex. In candidates supported with intra-aortic balloon pump (n = 1391, 14.6%), transplantation of higher-risk donor hearts did not adversely affect 1 year survival (HR: 0.80, 95% CI: [0.52-1.22], p = 0.30). Patients on durable left ventricular assist devices (LVAD) who received higher-risk donor hearts had comparable 1 year survival to continued LVAD support on the waitlist, but mortality was increased compared to those who received standard-risk donor hearts (HR: 1.37, 95% CI: [1.11-1.70], p = 0.004).
CONCLUSIONS
Patients requiring pre-HTx temporary MCS who received higher-risk donor hearts had comparable 1 year post-transplant survival to those who received standard-risk donor hearts. Stable patients on durable LVADs may benefit from waiting for standard-risk donor hearts.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.