BACKGROUND

The Singapore Cardiac Databank was designed to monitor the performance and outcomes of catheter ablation. We investigated the outcomes of paroxysmal supraventricular tachycardia (PSVT)-ablation in a prospective, nationwide, cohort study.

METHODS

Atrioventricular nodal re-entrant tachycardia (AVNRT), atrioventricular re-entry tachycardia (AVRT), or atrial tachycardia (AT)-ablations in Singapore from 2010 to 2018 were studied. Outcomes include acute success, periprocedural-complications, postoperative pacing requirement, arrhythmic recurrence and 1-year all-cause mortality.

RESULTS

Among 2260 patients (mean age 45 ± 18 years, 50% female, 57% AVNRT, 37% AVRT, 6% AT), overall acute success rates of PSVT-ablation was 98.4% and increased in order of AT, AVRT, and AVNRT (p < .001). Periprocedural cardiac tamponade occurred in two AVRT patients. A total of 15 pacemakers (6 within first 30-days, 9 after 30-days) were implanted (seven AV block, eight sinus node dysfunction [SND]), with the highest incidence of pacemaker implantation after AT-ablation (5% vs. 0.6% AVNRT vs. 0.1% AVRT, p < .001). Repeat ablations (0.9% AVNRT, 7% AVRT, 4% AT, p < .001) were performed in 78 (3.5%) patients and 13 (0.6%) patients died within a year of ablation. Among outcomes considered adjusting for age, sex, PSVT-type and procedure-time, AT was independently associated with 6-fold increased odds of total (adjusted odds ratio [AOR] 6.32, 95% confidence interval [CI] 1.95-20.53) and late (AOR 6.38, 95% CI 1.39-29.29) pacemaker implantation, while AVRT was associated with higher arrhythmic recurrence with repeat ablations (AOR 4.72, 95% CI 2.36-9.44) compared to AVNRT.

CONCLUSIONS

Contemporary PSVT ablation is safe with high acute success rates. Long-term outcomes differed by nature of the PSVT.

Для цитирования: Tan Eugene S J, Chan Siew Pang, Seow Swee-Chong, Teo Wee Siong, Ching Chi Keong, Chong Daniel T T, Tan Vern Hsen, Chia Pow-Li, Foo David C G, Kojodjojo Pipin, HRAS investigators. Outcomes of supraventricular tachycardia ablation: Results from the Singapore ablation and cardiac devices registry.. Pacing and clinical electrophysiology : PACE. 2021. DOI: 10.1111/pace.14410.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.