MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.hrthm.2021.03.006

Медицинская библиотека · Heart rhythm · 2021

Competing risks in patients with primary prevention implantable cardioverter-defibrillators: Global Electrical Heterogeneity and Clinical Outcomes study.

Waks Jonathan W, Haq Kazi T, Tompkins Christine, Rogers Albert J, Ehdaie Ashkan, Bender Aron, Minnier Jessica, Dalouk Khidir, Howell Stacey, Peiris Achille, Raitt Merritt, Narayan Sanjiv M, Chugh Sumeet S, Tereshchenko Larisa G

СтатьяМногоцентровое исследованиеПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Global electrical heterogeneity (GEH) is associated with sudden cardiac death in the general population. Its utility in patients with systolic heart failure who are candidates for primary prevention (PP) implantable cardioverter-defibrillators (ICDs) is unclear.

OBJECTIVE

The purpose of this study was to investigate whether GEH is associated with sustained ventricular tachycardia/ventricular fibrillation leading to appropriate ICD therapies in patients with heart failure and PP ICDs.

METHODS

We conducted a multicenter retrospective cohort study. GEH was measured by spatial ventricular gradient (SVG) direction (azimuth and elevation) and magnitude, QRS-T angle, and sum absolute QRST integral on preimplant 12-lead electrocardiograms. Survival analysis using cause-specific hazard functions compared the strength of associations with 2 competing outcomes: sustained ventricular tachycardia/ventricular fibrillation leading to appropriate ICD therapies and all-cause death without appropriate ICD therapies.

RESULTS

We analyzed 2668 patients (mean age 63 ± 12 years; 624 (23%) female; 78% white; 43% nonischemic cardiomyopathy; left ventricular ejection fraction 28% ± 11% from 6 academic medical centers). After adjustment for demographic, clinical, device, and traditional electrocardiographic characteristics, SVG elevation (hazard ratio [HR] per 1SD 1.14; 95% confidence interval [CI] 1.04-1.25; P = .004), SVG azimuth (HR per 1SD 1.12; 95% CI 1.01-1.24; P = .039), SVG magnitude (HR per 1SD 0.75; 95% CI 0.66-0.85; P < .0001), and QRS-T angle (HR per 1SD 1.21; 95% CI 1.08-1.36; P = .001) were associated with appropriate ICD therapies. Sum absolute QRST integral had different associations in infarct-related cardiomyopathy (HR 1.29; 95% CI 1.04-1.60) and nonischemic cardiomyopathy (HR 0.78; 95% CI 0.62-0.96) (Pinteraction = .022).

CONCLUSION

In patients with PP ICDs, GEH is independently associated with appropriate ICD therapies. The SVG vector points in distinctly different directions in patients with 2 competing outcomes.

Для цитирования: Waks Jonathan W, Haq Kazi T, Tompkins Christine, Rogers Albert J, Ehdaie Ashkan, Bender Aron, Minnier Jessica, Dalouk Khidir, Howell Stacey, Peiris Achille, Raitt Merritt, Narayan Sanjiv M, Chugh Sumeet S, Tereshchenko Larisa G. Competing risks in patients with primary prevention implantable cardioverter-defibrillators: Global Electrical Heterogeneity and Clinical Outcomes study.. Heart rhythm. 2021. DOI: 10.1016/j.hrthm.2021.03.006.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.