Atrial fibrillation burden and heart failure: Data from 39,710 individuals with cardiac implanted electronic devices.

Steinberg Benjamin A, Li Zhen, O'Brien Emily C, Pritchard Jessica, Chew Derek S, Bunch T Jared, Mark Daniel B, Nabutovsky Yelena, Greiner Melissa A, Piccini Jonathan P

СтатьяМногоцентровое исследованиеПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Atrial fibrillation (AF) and heart failure (HF) often accompany one another, and each is independently associated with poor outcomes. However, the association between AF burden and outcomes is poorly understood.

OBJECTIVE

The purpose of this study was to describe the association between device-based AF burden and HF clinical outcomes.

METHODS

We used a nationwide, remote monitoring database of cardiac implantable electronic devices (CIEDs) linked to Medicare claims. We included patients with nonpermanent AF, undergoing new CIED implant, stratified by baseline HF. The outcomes were new-onset HF, HF hospitalization, and all-cause mortality at 1 and 3 years.

RESULTS

We identified 39,710 patients who met inclusion criteria (25,054 with HF; 14,656 without HF). Patients with HF were younger (mean age 76.3 vs 78.5 years; P <.001), more often male (65% vs 54%; P <.001), and had higher mean CHA2DS2-VASc scores (5.4 vs 4.1; P <.001). Among those without HF, increasing device-based AF burden was significantly associated with increased risk of new-onset HF (adjusted hazard ratio [HR] 1.09 per 10% AF burden; 95% confidence interval [CI] 1.06-1.12; P <.001) and all-cause mortality (adjusted HR 1.05 per 10% AF burden; 95% CI 1.01-1.10; P = .012). Among patients with HF, increasing AF burden was significantly associated with increased risk of HF hospitalization (adjusted HR 1.05 per 10% AF burden; 95% CI 1.04-1.06; P <.001) and all-cause mortality (adjusted HR 1.06 per 10% AF burden; 95% CI 1.05-1.08; P <.001).

CONCLUSION

Among older patients with AF receiving a CIED, increasing AF burden is significantly associated with increasing risk of adverse HF outcomes and all-cause mortality.

Для цитирования: Steinberg Benjamin A, Li Zhen, O'Brien Emily C, Pritchard Jessica, Chew Derek S, Bunch T Jared, Mark Daniel B, Nabutovsky Yelena, Greiner Melissa A, Piccini Jonathan P. Atrial fibrillation burden and heart failure: Data from 39,710 individuals with cardiac implanted electronic devices.. Heart rhythm. 2021. DOI: 10.1016/j.hrthm.2021.01.021.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.