Cho Youngjin, Cho Sang Yeong, Oh Il Young, Lee Ji Hyun, Park Jin Joo, Lee Hae Young, Kim Kye Hun, Yoo Byung Su, Kang Seok Min, Baek Sang Hong, Jeon Eun Seok, Kim Jae Joong, Cho Myeong Chan, Chae Shung Chull, Oh Byung Hee, Choi Dong Ju

Аннотация

BACKGROUND: There are sparse data on the utilization rate of implantable cardioverter-defibrillator (ICD) and its beneficial effects in Korean patients with heart failure with reduced left ventricular ejection fraction (LVEF).

METHODS: Among 5,625 acute heart failure (AHF) patients from 10 tertiary university hospitals across Korea, 485 patients with reassessed LVEF ≤ 35% at least 3 months after the index admission were enrolled in this study. The ICD implantation during the follow-up was evaluated. Mortality was compared between patients with ICDs and age-, sex-, and follow-up duration matched control patients.

RESULTS: Among 485 patients potentially indicated for an ICD for primary prevention, only 56 patients (11.5%) underwent ICD implantation during the follow-up. Patients with ICD showed a significantly lower all-cause mortality compared with their matched control population: adjusted hazard ratio (HR) (95% confidence interval [CI]) = 0.39 (0.16-0.92), P = 0.032. The mortality rate was still lower in the ICD group after excluding patients with cardiac resynchronization therapy (adjusted HR [95% CI] = 0.09 [0.01-0.63], P = 0.015). According to the subgroup analysis for ischemic heart failure, there was a significantly lower all-cause mortality in the ICD group than in the no-ICD group (HR [95% CI] = 0.20 [0.06-0.72], P = 0.013), with a borderline statistical significance (interaction P = 0.069).

CONCLUSION: Follow-up data of this large, multicenter registry suggests a significant under-utilization of ICD in Korean heart failure patients with reduced LVEF. Survival analysis implies that previously proven survival benefit of ICD in clinical trials could be extrapolated to Korean patients.

TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT01389843.