BACKGROUND

New-onset conduction abnormalities (CAs) following transcatheter aortic valve replacement (TAVR) are associated with hospital rehospitalization and long-term mortality, but available predictors are sparse. This study sought to determine clinical predictors of new-onset left bundle branch block (LBBB) and new permanent pacemaker (PPM) implantation in patients undergoing TAVR.

METHODS AND

RESULTS

We enrolled 290 patients who received SAPIEN 3 (Edwards Lifesciences, Irvine, CA, USA; n=217) or Evolut R (Medtronic, Minneapolis, MN, USA; n=73) from a prospective registry at Nouvel Hôpital Civil, Strasbourg, France between September 2014 and February 2018. Of 242 patients without pre-existing LBBB, 114 (47%) experienced new-onset LBBB and/or new PPM implantation. A difference between membranous septal length and implantation depth (∆MSID) was the only predictor of CAs for both types of valves. In the multivariate analysis, PR interval and ∆MSID remained as sole predictors of CAs. The risk for adverse clinical events, including all-cause death, myocardial infarction, stroke, and heart failure hospitalization, was higher for patients with CAs as compared with patients without CAs (hazard ratio: 2.10; 95% confidence interval: 1.26 to 3.57; P=0.004).

CONCLUSIONS

Computed tomography assessment of membranous septal anatomy and implantation depth predicted CAs after TAVR with new-generation valves. Future studies are required to identify whether adjustment of the implantation depth can reduce the risk of CAs and adverse clinical outcomes.

Для цитирования: Matsushita Kensuke, Kanso Mohamad, Ohana Mickael, Marchandot Benjamin, Kibler Marion, Heger Joe, Peillex Marilou, Trimaille Antonin, Hess Sébastien, Grunebaum Lelia, Reydel Antje, De Poli Fabien, Leddet Pierre, Rischner Jérôme, Plastaras Philoktemon, Jesel Laurence, Morel Olivier, Ohlmann Patrick. Periprocedural Predictors of New-Onset Conduction Abnormalities After Transcatheter Aortic Valve Replacement.. Circulation journal : official journal of the Japanese Circulation Society. 2020. DOI: 10.1253/circj.cj-20-0257.