MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.hrthm.2020.08.014

Медицинская библиотека · Heart rhythm · 2020

N-terminal pro-B-type natriuretic peptide is a specific predictor of appropriate device therapies in patients with primary prevention implantable cardioverter-defibrillators.

Sroubek Jakub, Matos Jason, Locke Andrew, Kaplinskiy Vladimir, Levine Yehoshua C, Shen Changyu, Buxton Alfred E

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Sudden death risk stratification of patients with left ventricular systolic dysfunction remains challenging. Retrospective studies have suggested N-terminal pro-B-type natriuretic peptide (NT-proBNP) may be a useful risk stratification tool.

OBJECTIVE

The purpose of this study was to ascertain the utility of NT-proBNP as a predictor of appropriate implantable cardioverter-defibrillator (ICD) therapies in primary prevention ICD recipients.

METHODS

This was a prospective study of 342 stable patients with left ventricular ejection fraction ≤40% who received a primary prevention ICD. NT-proBNP assay was performed at the time of device implant and used as a dichotomized variable (1st-3rd NT-proBNP quartiles vs 4th NT-proBNP quartile) to predict primary (appropriate ICD therapies) and secondary (death, ICD-deactivation, chronic inotropic support, transplant) outcomes.

RESULTS

Median follow-up was 35.0 months (interquartile range 15.2-55.3). In unadjusted analyses, NT-proBNP predicted both primary (hazard ratio [HR] 1.89; 95% confidence interval [CI] 1.00-3.56); P = .049) and secondary outcomes (HR 2.13; 95% CI 1.18-3.85; P =.012). Multivariable analysis reaffirmed NT-proBNP as a primary outcome predictor (HR 4.31; 95% CI 1.92-9.70; P <.001) but not as a secondary outcome predictor (HR 1.23; 95% CI 0.61-2.50; P = .564). Instead, secondary outcome was predicted by patient age and renal function. In an unadjusted subanalysis limited to patients with blood urea nitrogen <30 mg/dL, NT-proBNP remained a primary endpoint predictor (HR 2.51; 95% CI 1.25-5.05; P = .010) but not a secondary endpoint predictor (HR 1.34; 95% CI 0.52-3.44; P = .541). Receiver operating analyses at 2- and 3-year follow-up timepoints confirmed that NT-proBNP significantly improved the performance of multivariable models designed to predict future appropriate ICD therapies.

CONCLUSION

In multivariable analysis, NT-proBNP is a reasonable and specific predictor of future appropriate device therapies in primary prevention ICD recipients. In contrast, adjusted NT-proBNP does not predict all-cause mortality.

Для цитирования: Sroubek Jakub, Matos Jason, Locke Andrew, Kaplinskiy Vladimir, Levine Yehoshua C, Shen Changyu, Buxton Alfred E. N-terminal pro-B-type natriuretic peptide is a specific predictor of appropriate device therapies in patients with primary prevention implantable cardioverter-defibrillators.. Heart rhythm. 2020. DOI: 10.1016/j.hrthm.2020.08.014.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.