MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jemermed.2019.11.022

Медицинская библиотека · The Journal of emergency medicine · 2020

Mechanical Chest Compression Device for Out-Of-Hospital Cardiac Arrest: A Nationwide Observational Study.

Jung Eujene, Park Jeong Ho, Lee Sun Young, Ro Young Sun, Hong Ki Jeong, Song Kyoung Jun, Ryu Hyun Ho, Shin Sang Do

СтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

BACKGROUND

There are few studies on the use of a mechanical chest compression (meCC) device during transport in patients with out-of-hospital cardiac arrest (OHCA).

OBJECTIVE

The aim of our study was to compare the performance of an meCC device with that of manual chest compression during transport after OHCA.

METHODS

This study used data from the national cardiac arrest registry of patients with OHCA of presumed cardiac etiology. The primary exposure was the use of an meCC device by an Emergency Medical Services provider while transporting a patient to the emergency department. The primary endpoint was good cerebral performance category at discharge. We compared survival and neurologic outcomes between an meCC device group and a manual chest compression group. We also performed an interaction analysis to assess changes in study outcomes of meCC device use by the initial electrocardiogram (ECG) and transport time interval (TTI).

RESULTS

Among 30,021 adult patients after OHCA with presumed cardiac etiology, an meCC device was used in 2357 (7.6%). After adjustment for possible confounders, there were no significant differences with respect to good neurologic recovery in the outcomes of patients who were treated with an meCC device and those who received manual chest compression (adjusted odds ratio [AOR] 0.66; 95% confidence interval [CI] 0.43-1.02) and survival to discharge (AOR 0.83; 95% CI 0.64-1.06). In the interaction model, the AOR of the meCC device study outcome did not interact with the initial ECG and TTI.

CONCLUSIONS

The meCC device did not show better study outcomes than manual compression.

Для цитирования: Jung Eujene, Park Jeong Ho, Lee Sun Young, Ro Young Sun, Hong Ki Jeong, Song Kyoung Jun, Ryu Hyun Ho, Shin Sang Do. Mechanical Chest Compression Device for Out-Of-Hospital Cardiac Arrest: A Nationwide Observational Study.. The Journal of emergency medicine. 2020. DOI: 10.1016/j.jemermed.2019.11.022.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.